1.5 Examples of Servo System Configurations
1-17
1
Ou
tline
1.5
Examples of Servo System Configurations
This section describes examples of basic servo system configuration.
1.5.1
Connecting to SGDV-
F11A SERVOPACK
∗1.
Before connecting an external regenerative resistor to the SERVOPACK, refer to
3.7 Connecting Regenerative Resis-
tors
.
∗2.
Use a 24-VDC power supply. (Not included.)
SGDV-
F11A
SERVOPACK
SGMJV/SGMAV/SGMPS/SGMCS
Servomotor
Power supply
Single-phase 100 VAC
R
T
100 VAC
Noise filter
Molded-case
circuit breaker
(MCCB)
Protects the power
line by shutting the
circuit OFF when
overcurrent is
detected.
Eliminates
external noise from
the power line.
Magnetic
contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
Brake power supply
∗
2
Magnetic contactor
Regenerative
resistor
∗
1
Used for a servomotor
with a brake.
Turns the brake power supply
ON and OFF.
Install a surge absorber.
Servomotor main
circuit cable
Encoder cable
Battery case
(when an absolute
encoder is used.)
I/O signal cable
Connection cable
for digital operator
Connection cable
for personal computer
Digital
operator
Personal
computer
Connect to the
MECHATROLINK-
II
Safety function
devices
Host controller
When not using the safety function,
use the SERVOPACK with the safety
function’s jumper connector inserted.
When using the safety function,
use the safety connection cable.
Safety
connection cable