5.2 Specifications and Ratings: Small Capacity
5.2.4 Servomotor Overload Protection Characteristics
5-7
5
Specifications, Ratings, and Exter
nal Dimensions of SGM7F Servomotors
5.2.4
Servomotor Overload Protection Characteristics
The overload detection level is set for hot start conditions with a Servomotor surrounding air tem-
perature of 40
°
C.
Note: The above overload protection characteristics do not mean that you can perform continuous duty operation
with an output of 100% or higher.
Use the Servomotor so that the effective force remains within the continuous duty zone. Refer to the following
section for the effective torque.
5.2.3 Torque-Motor Speed Characteristics
10000
1000
100
10
1
SGM7F-
A and -
B
SGM7F-08C
0
50
100
150
200
250
300
10000
1000
100
10
1
SGM7F-17C and -25C
0
50
100
150
200
250
300
SGM7F-35D
10000
1000
100
10
1
0
50
100
150
200
250
300
SGM7F-16D
10000
1000
100
10
1
0
50
100
150
200
250
300
Detection time (s)
Torque reference (%)
Detection time (s)
Torque reference (%)
Detection time (s)
Torque reference (%)
Detection time (s)
Torque reference (%)
Detection time (s)
Torque reference (%)
10000
1000
100
10
1
0
50
100
150
200
250
300
350