4 Feed Axis Operation
4.3.2 Using Subcommands to Change Parameters
4-12
Refer to
3.4.8 Write Servo Parameter Subcommand (SVPRM_WR: 41H)
in the
Σ
-V-SD AC Servo Drives
Σ
-V-
SD Series User’s Manual MECHATROLINK-III Standard Servo Profile Commands
(Manual No.: SIEP
S800000 76) for details on the SVPRM_WR (41 hex) command.
Example: Changing the Speed Loop Gain Parameter (Pn104) in Gain Bank 1
Specification Method
SUBCMD SVCMD_WR = 41 hex
NO = 104: Speed Loop Gain Pn104
SIZE = 2: 2 bytes
MODE = 10 hex: Write to RAM
PARAMETER =
: Data to write
When RSUBCMD is SVPRM_WR (41 hex) and SUB_STAT.SUBCMDRDY is 1 in the response data, the
parameter has been written successfully. The time required to write the parameter depends on the operating
status of the SERVOPACK, but on average, approximately 4 ms is required.
Gain Setting Parameter
Gain Bank
Gain 0
Gain 1
Gain 2
Gain 3
Speed loop gain
Pn100
Pn104
Pn12B
Pn12E
Speed loop integral time constant
Pn101
Pn105
Pn12C
Pn12F
Position loop gain
Pn102
Pn106
Pn12D
Pn130
Torque reference filter
Pn401
Pn412
Pn413
Pn414