9.1 SERVOPACK Monitors
9-3
Monitoring
• Monitor Types
• Common Monitor Selection
Selection
Code
Monitor
Name
Description
Remarks
0
APOS
Feedback position
−
1
CPOS
Command position
−
2
PERR
Position deviation
−
3
LPOS1
Latch position 1
−
4
LPOS2
Latch position 2
−
5
FSPD
Feedback speed
−
6
CSPD
Reference speed
−
7
TRQ
Reference torque
−
8
ALARM
Detailed information on the current
alarm
If an alarm occurs after a warning, the alarm is dis-
played.
9
MPOS
Position reference
Input reference position for the position loop
MPOS = APOS + PERR
A
−
Reserved.
−
B
−
Reserved.
−
C
CMN1
Common monitor 1
Selects the monitor data specified in Common Param-
eter 89.
D
CMN2
Common monitor 2
Selects the monitor data specified in Common Param-
eter 8A.
E
OMN1
Optional monitor 1
Selects the monitor data specified in Pn824.
F
OMN2
Optional monitor 2
Selects the monitor data specified in Pn825.
Param-
eter No.
Size
Name
Setting
Range
Setting Unit
(Resolution)
Factory
Setting
When
Enabled
Classi-
fication
89
PnB12
4
Monitor Selection for SEL_MON1
(CMN1)
0 to 9
−
0000
Immediately
Setup
0000 hex TPOS (target position in reference coordinates)
0001 hex IPOS (reference position in reference coordinates)
0002 hex
POS_OFFSET (offset value set with the POS_SET
command)
0003 hex TSPD (target speed)
0004 hex SPD_LIM (speed limit value)
0005 hex TRQ_LIM (torque limit value)
Содержание E-V-SD Series