5.6 Winding Selection
5-33
Spindle Axis
Operation
5.6.13
Related Alarms
The following table lists all relevant alarms.
Alarm
Number
Name
Description
Stop
Method
Reset
A.052
Motor Type Setting Mismatch
The Motor Type (Pn01E.0) does not match the
motor parameter (PnF40.0).
Pn001.0
Required
A.053
Winding Selection Setting Mis-
match
The Winding Selection (Pn01E.1) does not
match the motor parameter (PnF40.2).
Pn001.0
Required
A.054
Unsupported Winding Selection
Alarm
The SERVOPACK and motor are not compat-
ible for winding selection (winding selection
is used for SERVOPACKs that use a charge
pump together with a magnetic motor).
Pn001.0
Required
A.540
Overspeed (during Low-speed
Winding)
The low-speed winding maximum speed was
exceeded during low-speed winding.
Pn001.0
Auto reset
A.690
Winding Selection Operation
Fault
• During the winding selection operation
check that is performed when the power is
turned ON, the winding selector did not
change according to the internal command.
• Winding changeover was not completed
within two seconds of receiving the wind-
ing selection command.
• Chattering occurred in the winding selector
when the winding selection command was
not received.
Pn001.0
Required
A.C52
Magnetic Pole Detection Incom-
plete
• The servo was turned ON before the execu-
tion of magnetic pole detection was com-
pleted.
• Magnetic pole detection was attempted dur-
ing high-speed winding.
Pn001.0
Auto reset