9.5 I/O Monitoring
9-13
Monitoring
9.5
I/O Monitoring
During machine trial operation and operation confirmation, the bit commands from the host controller, SER-
VOPACK status bits, and SERVOPACK input signal status are checked on the host controller GUI.
This allows for smooth trial operation confirmation and troubleshooting.
The following items are displayed on the host controller for I/O monitoring:
• Output signals: CMD_CTRL, SUB_CTRL, SVCMD_CTRL, and SVCMD_IO
• Input signals: CMD_STAT, SUB_STAT, SVCMD_STAT, and SVCMD_IO
If there are multiple SERVOPACKS connected to the host controller, it can be helpful to display the status of
all I/O signals (bits) at the same time on the host controller GUI.