644
YASKAWA ELECTRIC
SIEP C710617 19A YASKAWA AC Drive CR700 Technical Manual
F7-79: PZD10 Read
No.
(Hex.)
Name
Description
Default
(Range)
F7-79
(0793)
PZD10 Read
Sets the MEMOBUS/Modbus address for PZD10 (PPO Read). A value of 0
will disable the PZD10 (PPO input) load operation from the MEMOBUS/
Modbus register.
0
◆
H: Terminal Functions
H parameters
are used to assign functions to external input and output terminals.
■
H1: Digital Inputs
H1 Parameters
set the MFDI terminal functions.
H1-01 to H1-10 Terminal S1 to S10 Function Selection
The drive has ten MFDI terminals. The following table lists the functions according to the default settings.
No.
Name
Default
Function
H1-01
Terminal S1 Function Selection
40
Forward RUN (2-Wire)
H1-02
Terminal S2 Function Selection
41
Reverse RUN (2-Wire)
H1-03
Terminal S3 Function Selection
24
External Fault (NO-Always-
Coast)
H1-04
Terminal S4 Function Selection
14
Fault Reset
H1-05
Terminal S5 Function Selection
0
Brake Release Check
H1-06
Terminal S6 Function Selection
3
Multi-Step Speed Reference 1
H1-07
Terminal S7 Function Selection
4
Multi-Step Speed Reference 2
H1-08
Terminal S8 Function Selection
9
Baseblock Command (N.C.)
H1-09
Terminal S9 Function Selection
F
Not Used
H1-10
Terminal S10 Function Selection F
Not Used
Refer to the following table and use
H1-xx [MFDI Function Selection]
to set the function.
Table 11.26 MFDI Function Selections
Setting
Function
0
Brake Release Check
2
External Reference 1/2 Selection
3
Multi-Step Speed Reference 1
4
Multi-Step Speed Reference 2
5
Multi-Step Speed Reference 3
6
Jog Reference Selection
7
Accel/Decel Time Selection 1
Baseblock Command (N.O.)
Baseblock Command (N.C.)
A
Accel/Decel Ramp Hold
B
Overheat Alarm (oH2)
C
Analog Terminal Enable Selection
D
V/f w/PG Encoder Feedback Ignore
E
ASR Integral Reset
F
Not Used
10
Up Command
11
Down Command
Setting
Function
12
Forward Jog
13
Reverse Jog
14
Fault Reset
15
Fast Stop (N.O.)
16
Motor 2 Selection
17
Fast Stop (N.C.)
1A
Accel/Decel Time Selection 2
1B
Programming Lockout
1E
Reference Sample Hold
20 to 2F
External Fault
30
Light-load Accel 1 Enabled
31
Forward Travel Limit (N.O.)
32
Forward Travel Limit (N.C.)
33
Reverse Travel Limit (N.O.)
34
Reverse Travel Limit (N.C.)
35
Impact Stop Enable
36
Light-load Accel 2 Enabled
V/f
CL-V/f
OLV
CLV
AOLV