d3: Jump Frequency
No.
(Hex.)
Name
Description
Default
(Range)
d3-01
(0294)
Jump Frequency 1
Sets the median value of the frequency band that the drive will avoid.
0.0 Hz
(Determined by A1-
02)
d3-02
(0295)
Jump Frequency 2
Sets the median value of the frequency band that the drive will avoid.
0.0 Hz
(Determined by A1-
02)
d3-03
(0296)
Jump Frequency 3
Sets the median value of the frequency band that the drive will avoid.
0.0 Hz
(Determined by A1-
02)
d3-04
(0297)
Jump Frequency
Width
Sets the width of the frequency band that the drive will avoid.
1.0 Hz
(Determined by A1-
02)
■
d4: Frequency Ref Up/Down & Hold
No.
(Hex.)
Name
Description
Default
(Range)
d4-01
(0298)
Freq Reference Hold
Selection
Sets whether to save the frequency reference when the Stop command is
entered or the power supply is shut off.
0 : Disabled
1 : Enabled
0
(0, 1)
d4-10
(02B6)
Up/Down Freq
Lower Limit Select
Sets the lower frequency limit for the Up/Down function.
0 : Greater of d2-02 or Analog
1 : d2-02
0
(0, 1)
■
d6: Field Forcing
No.
(Hex.)
Name
Description
Default
(Range)
d6-03
(02A2)
Field Forcing
Selection
Sets the field forcing function.
0 : Disabled
1 : Enabled
0
(0, 1)
d6-06
(02A5)
Field Forcing Limit
Sets the maximum level that Field Forcing can increase the excitation
current reference as a percentage of
E2-03 [Motor No-Load Current]
.
Usually it is not necessary to change this setting.
400%
(100 - 400%)
■
d7: Offset Frequency
No.
(Hex.)
Name
Description
Default
(Range)
d7-01
(02B2)
RUN
Offset Frequency 1
Sets the value to add to or subtract from the frequency reference when
H1-
xx = 44 [MFDI Function Select = Add Offset Frequency 1 (d7-01)]
as a
percentage of
E1-04 [Maximum Output Frequency]
.
0.0%
(-100.0 - +100.0%)
d7-02
(02B3)
RUN
Offset Frequency 2
Sets the value to add to or subtract from the frequency reference when
H1-
xx = 45 [MFDI Function Select = Add Offset Frequency 2 (d7-02)]
as a
percentage of
E1-04 [Maximum Output Frequency]
.
0.0%
(-100.0 - +100.0%)
d7-03
(02B4)
RUN
Offset Frequency 3
Sets the value to add to or subtract from the frequency reference when
H1-
xx = 46 [MFDI Function Select = Add Offset Frequency 3 (d7-03)]
as a
percentage of
E1-04 [Maximum Output Frequency]
.
0.0%
(-100.0 - +100.0%)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV