A Plug-in Voice cannot be selected even when a Plug-in Board has been installed.
• Check whether the SLOT lamp (from SLOT1 - 3) corresponding to the selected PLG button ([PLG1] - [PLG3]) is turned on
or off.
• When selecting a User bank, are any Voices stored into the User bank?
In the default settings, User banks for Plug-in Voice contain no Voices. You must the select the Preset bank or create a
User Voice.
• Check whether the PLG which corresponds to the PLG100-XG slot is selected or not.
The Voice on the PLG100-XG cannot be selected in the Voice mode or Performance mode.
• Check whether the PLG which corresponds to the PLG100-VH slot is selected or not.
The PLG100-VH contains no Voices for selection, since it is an Effect Plug-in Board.
■
The Plug-in Board does not work.
Is the lamp of the corresponding slot number to which the Plug-in board has been installed lit? (page 18)
• Has the PLG100-VH been installed to slot 2 or 3?
The PLG100-VH can be installed only to slot 1.
• Has the PLG100-XG been installed to slot 1 or 2?
The PLG100-XG can be installed only to slot 3.
■
Data communication between the computer and the S90 ES does not work properly.
• Check whether the Port setting on the computer is appropriate or not.
• Is the cable setting (MIDI, USB, mLAN) in the Utility mode appropriate?
■
The S90 ES does not sound properly even when playing back the song data on the computer or the
MIDI instrument connected to the S90 ES.
• Make sure to set the S90 ES to the Multi mode. To play back the multiple channels simultaneously, select multi mode.
■
MIDI bulk data transmission/reception does not work properly.
• Is Bulk data receive protection enabled?
Turn the Receive Bulk parameter to “on.”
• When receiving recorded data with the internal Bulk Dump function, the device number must be set to the same value as
that used when transmitting/recording.
• When transmission does not work properly, is the device number of the MIDI instrument connected to the S90 ES set to
match the DeviceNo. parameter?
• When using the Voice Editor/Multi Part Editor, have you set a sufficient Dump Interval?
The Dump Interval in the Editor Setup dialog must be set to 20ms or greater. For details refer to the PDF manual included
with the Editor.
■
Data cannot be saved in the USB storage device
• Is the connected USB storage device write protected? (Write-protect should be set to off for saving data.)
• Is the connected USB storage device properly formatted?
■
Cannot enter the Edit mode
• Is the Category Search function turned on?
After exiting from the Category Search function, press the [EDIT] button.
• Is the S90 ES in the File mode?
After exiting from the File mode, press the [EDIT] button.
[VOICE]
→
[UTILITY]
→
[F5] MIDI
→
[SF4] OTHER
→
[UTILITY]
→
[F5] MIDI
→
[SF2] SWITCH
→
[UTILITY]
→
[F5] MIDI
→
[SF1] CH
→
[UTILITY]
→
[F5] MIDI
→
[SF1] CH
→
[FILE]
→
[F1] CONFIG
→
[SF2] FORMAT (page 168)