3 - 72
CHK
ADJ
CHECKING AND CHARGING THE BATTERY
Charging method using a constant voltage charger
Measure the open-circuit
voltage prior to charging.
NOTE:
Set the charging time to a maxi-
mum of 20 hours.
Connect a charger and
ammeter to the battery
and start charging.
Is the amperage higher
than the standard charg-
ing amperage written on
the battery?
Charge the battery until the charging
voltage reaches 15 V.
This type of battery charger cannot
charge an MF battery. A variable-
voltage charger is recommended.
Leave the battery unused for more than
30 minutes before measuring its open-cir-
cuit voltage.
12.8 V
→
Charging is complete.
12.0 ~ 12.7 V
→
Recharging is required.
Under 12.0 V
→
Replace the battery.
Constant amperage chargers are not
suitable for charging MF batteries.
CAUTION:
NOTE:
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage.
Charger
Ammeter
Voltmeter
NO
YES
Содержание GRIZZLY 700 FI YFM7FGPW
Страница 1: ...LIT 11616 20 11 3B4 28197 10 YFM7FGPW SERVICE MANUAL ...
Страница 47: ...2 11 SPEC ENGINE SPECIFICATIONS Cylinder head tightening sequence 3 1 4 2 7 8 5 6 ...
Страница 274: ...6 2 FI FUEL INJECTION SYSTEM 6 ...
Страница 482: ...10 7 TRBL SHTG ...
Страница 484: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN PRINTED IN U S A ...