Page 147
FT
DX
9000MP O
PERATION
M
ANUAL
MMMMM
ENU
ENU
ENU
ENU
ENU
M M M M M
ODE
ODE
ODE
ODE
ODE
AGC G
ROUP
001. MAIN-FAST-DELAY
Function
: Sets the delay time for the AGC FAST
mode of the Main band (VFO-A) receiver.
Available Values
: 20 ~ 4000 msec (20 msec/step)
Default Setting
: 300 msec
002. MAIN-FAST-HOLD
Function
: Sets the hang time of the AGC peak volt-
age for the AGC FAST mode of the Main band (VFO-
A) receiver.
Available Values
: 0 ~ 2000 msec (20 msec/step)
Default Setting
: 20 msec
003.MAIN-MID-DELAY
Function
: Sets the delay time for the AGC MID mode
of the Main band (VFO-A) receiver.
Available Values
: 20 ~ 4000 msec (20 msec/step)
Default Setting
: 700 msec
004. MAIN-MID-HOLD
Function
: Sets the hang time of the AGC peak volt-
age for the AGC MID mode of the Main band (VFO-
A) receiver.
Available Values
: 0 ~ 2000 msec (20 msec/step)
Default Setting
: 20 msec
005. MAIN-SLOW-DELAY
Function
: Sets the delay time for the AGC SLOW
mode of the Main band (VFO-A) receiver.
Available Values
: 20 ~ 4000 msec (20 msec/step)
Default Setting
: 2000 msec
006. MAIN-SLOW-HOLD
Function
: Sets the hang time of the AGC peak volt-
age for the AGC SLOW mode of the Main band (VFO-
A) receiver.
Available Values
: 0 ~ 2000 msec (20 msec/step)
Default Setting
: 20 msec
007. SUB-FAST-DELAY
Function
: Sets the delay time for the AGC FAST
mode of the Sub band (VFO-B) receiver.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 300 msec
008. SUB-FAST-HOLD
Function
: Sets the hang time of the AGC peak volt-
age for the AGC FAST mode of the Sub band (VFO-
B) receiver.
Available Values
: 0 ~ 2000 msec (20 msec/step)
Default Setting
: 20 msec
009. SUB-MID-DELAY
Function
: Sets the delay time for the AGC MID mode
of the Sub band (VFO-B) receiver.
Available Values
: 20 ~ 4000 msec (20 msec/step)
Default Setting
: 700 msec
010. SUB-MID-HOLD
Function
: Sets the hang time of the AGC peak volt-
age for the AGC MID mode of the Sub band (VFO-B)
receiver.
Available Values
: 0 ~ 2000 msec (20 msec/step)
Default Setting: 20 msec
011. SUB-SLOW-DELAY
Function
: Sets the delay time for the AGC SLOW
mode of the Sub band (VFO-B) receiver.
Available Values
: 20 ~ 4000 msec (20 msec/step)
Default Setting
: 2000 msec
012. SUB-SLOW-HOLD
Function
: Sets the hang time of the AGC peak volt-
age for the AGC SLOW mode of the Sub band (VFO-
B) receiver.
Available Values
: 0 ~ 2000 msec (20 msec/step)
Default Setting
: 20 msec
Содержание FT DX 9000MP CONTEST - DATA MANAGEMENT OPERATION
Страница 1: ...FTDX 9000MP Operation Manual...
Страница 2: ......
Страница 125: ...Page 123 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...
Страница 171: ...Page 169 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...
Страница 175: ...Page 173 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...
Страница 178: ...Page 176 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...