Operation Manual
58
Operation
Fig 67. Engine Indicator Chart
CHECK
ENGINE
ENGINE
SHUT
DOWN
DEF LEVEL
EXHAUST
SYSTEM
CLEANING
(ESC)
HIGH
EXHAUST
TEMP
REGEN
DISABLED
LOW
COOLANT
LEVEL
WATER
IN FUEL
WAIT TO
START
ENGINE
SERVICE
NO FAULTS
ENGINE OPERATING NORMALLY
ON
MINOR FAULT
ENGINE OPERATING NORMALLY
ON
ON
SEVERE FAULT
ENGINE OPERATING WITH REDUCED POWER
ON
FLASH
VERY SEVERE FAULT
ENGINE OPERATING WITH MAX DE-RATE; SHUT ENGINE DOWN AS
SOON AS POSSIBLE. ENGINE MAY SHUT DOWN AUTOMATICALLY.
ON
DEF LEVEL LOW
ADD DEF
FLASH
DEF LEVEL VERY LOW
ADD DEF
ON
FLASH
DEF LEVEL CRITICALLY LOW
ENGINE POWER WILL BE DERATED SOON; ADD DEF AS SOON AS
POSSIBLE
ON
ON
FLASH
DEF LEVEL IS ZERO
ENGINE POWER DERATED OR LIMITED TO IDLE; ADD DEF
IMMEDIATELY
ON
EXCESSIVE SOOT LOADING MANUAL ESC REGEN RECOMMENDED
ON
ON
SERIOUS SOOT LOADING
MANUAL ESC REGEN REQUIRED; ENGINE OPERATING WITH
REDUCED POWER
FLASH
ON
HIGH EXHAUST TEMP
MANUAL ESC REGEN IN PROCESS
ON
HIGH EXHAUST TEMP
AUTO ESC REGEN IN PROCESS
ON
ESC REGEN DISABLED
ESC REGEN DISABLED DUE TO OPERATOR
ON
LOW COOLANT LEVEL
ADD COOLANT TO SURGE TANK
ON
WATER IN FUEL
DRAIN WATER FROM FUEL FILTER
ON
WAIT TO START
DO NOT START ENGINE UNTIL INDICATOR TURNS OFF
ON
ENGINE SERVICE
PERFORM ENGINE SERVICE
INDICATION
DESCRIPTION
during a manual regeneration.
EXHAUST SYSTEM CLEANING (ESC)
INDICATOR
The ESC Indicator will be displayed by itself
when a manual regeneration is recommended.
The ESC Indicator will be displayed with
the Check Engine Indicator when a manual
regeneration is required. The engine is
operating with reduced power.
A flashing ESC Indicator will be displayed
with the HEST Indicator when the exhaust
temperature is elevated due to a manual
regeneration. The forklift must not be operated
in this condition.
HIGH EXHAUST TEMPERATURE (HEST)
INDICATOR
The HEST Indicator will be displayed by itself
when the exhaust temperature is elevated due
to an automatic regeneration. The forklift may
be operated in this condition as long as there
is no concern for operating with high exhaust
temperature.
The HEST Indicator will be displayed with
a flashing ESC Indicator when the exhaust
temperature is elevated due to a manual
regeneration. The forklift must not be operated
in this condition.
ESC REGEN DISABLED INDICATOR
The ESC Regen Disabled indicator will be
displayed if the ESC Regen has been manually
disabled by the user. The forklift should only be
operated in this condition if it is in an area where
the high exhaust temperature could cause
problems, such as near combustibles. As soon
as the concern for high exhaust temperature
subsides, the automatic regeneration should
be enabled by pressing the Enter button
or Regen soft button to bring up the After
Treatment Control menu and then pressing the
Regen Mode Auto soft button.
Содержание XR3034
Страница 1: ...Operation and Safety Manual PN 24941 001 Tier 4 Final ...
Страница 24: ...Operation Manual 24 Labels 7 18015 001 8 18016 001 11 18018 002 12 18019 001 9 18017 001 10 18018 001 ...
Страница 25: ...Operation Manual 25 Labels 13 18020 001 14 18021 001 17 18025 001 18 18026 001 15 18022 001 16 18023 001 ...
Страница 75: ...Operation Manual 75 Lockout Tagout Do Not Operate Tags ...
Страница 76: ...PN 24941 001 XR 3034 Tier 4 Final 1415 W BONANZA RD LAS VEGAS NV 89106 702 636 2969 800 497 1704 www XMFG com ...