71
5-3-8. Command pulse prohibition (/INHIBIT)
To stop the commnad pulse input in position control mode. When /INHIBIT signal is ON, the
command pulse stop counting.
Input signal setting:
5-3-9. Positoin pulse difference
When the pulse difference over the limit value in position control mode, servo will alarm. This limit
value is pulse difference limit.
P0-23
Pulse difference limit
Unit
Default value
Range
Suitable
mode
Change
Effective
256
commands
50000
0~65535
6
Any
At once
When the P0-23=0, it will now detect the pulse difference value.
5-4
.
Speed control (analog voltage command) (Only for
DS3-PQA)
Basic parameters
Parameter
Name
Reference
P0-01
Select the control mode
5-4-1
P3-00
V-REF distribution
5-4-2
P3-01
Rated speed of the corresponding analog voltage
P3-02
Analog voltage speed filter
P3-03
Speed command input dead zone voltage
P3-14
Forward direction max speed command limit
P3-15
Reverse direction max speed command limit
P5-20
Servo ON signal /S-ON
5-2-1
Other parameters
Key words
Parameter
Name
Reference
Zero drift
F1-03
Analog voltage speed command offset
5-4-3
Parameter
Signal
Default
Suitable
mode
Modify Effective
Modify
P5-32
/INHIBIT
n.0000
6
Any
At once
Range: 0000-0015. When it
set to 0001, it means input
from SO1.
Note: /INHIBIT can be input from input terminal by setting P5-32. Please refer to chapter 5-12-1
(
alarm E-100
)
Normal
control
(
alarm E-100
)
Pulse
difference
0
P0-23