38
P0-25= power value, P0-26= resistor
value (see chapter 3-1-4)
P+/P-
Bus terminal
Real-time check the bus voltage, please
take attention of this terminal
DS3-21P5-PTA, DS3-22P3-PTA
Terminal Function
Explanation
R/S/T
Power supply input of
main circuit
DS3-21P5/22P3-PTA
3 phases AC 200
~
240V, 50/60Hz
Note: if using single phase 220V, please
connect power supply to R and T,
otherwise it will affect power-off
retentive function.
DS3-41P5-PTA
3 phases AC 360~400V, 50/60Hz
●
Vacant
-
U, V, W
Motor terminals
Connect the motor
Terminal
Color
U
brown
V
black
W
blue
PE
Yellow green
P+, D, C
Internal
regenerative
resistor
Short P+ and D, disconnect P+ and C,
set P0-24=0
External
regenerative
resistor
Connect regenerative resistor between
P+ and C, disconnect P+ and D, set
P0-24=1,
P0-25=power
value,
P0-26=resistor value (see chapter 3-1-4)
Ground
Connect to ground terminal of motor,
then connect to the ground
DS3-43P0-PTA
Terminal Function
Explanation
R/S/T
Power supply input of
main circuit
3 phases AC 360
~
400V, 50/60Hz
●
Vacant
U, V, W
Motor terminals
Connect the motor
Terminal
Color
U
brown
V
black
W
blue
PE
Yellow green
Note: the ground wire is on the cooling
fin, do not connect to P+ or P-, please
check it before power on.
P+, D, C
Internal
regenerative
resistor
Short P+ and D, disconnect P+ and C,
set P0-24=0
External
regenerative
resistor
Connect regenerative resistor between
P+ and C, disconnect P+ and D, set
P0-24=1,
P0-25=power
value,
P0-26=resistor value (see chapter 3-1-4)
R
S
T
.
U
V
W
P+
D
C
R
S
T
.
U
V
W
P+
D
C
P-
.