55
4. At this time the panel displays the value in P3-09, and the last decimal “0” is blinking. Press ENTER
to left shift the blinking decimal. Press INC, DEC or ENTER key to modify the value to 3000, and
press and hold ENTER to confirm.
The parameter in P3-09 in changed from 2000 to 3000.
Repeat steps 2 to 4 to change the parameter again.
5. Press STATUS/ESC key to return.
when the parameters are over the setting range, the drive will show E-021 alarm.
4-7
.
Change the motor code
One servo drive can match several servo motors with same power level. Before using the servo system,
please make sure the motor code on the servo motor label is the same to P0-33.
Motor label
If the servo motor code set error, the servo will show E-310 alarm. Please clean the alarm
through F0-00 then set the motor code again.
P0-33
Re-power
On servo
Keep press
ENTER
Finish
the setting
confirm
Input
motor code
Keep press
ENTER
Содержание DS3 series servo