![Xenics Manx-512 SQ CXP 130 Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/xenics/manx-512-sq-cxp-130/manx-512-sq-cxp-130_user-manual_3289592068.webp)
User Manual
Manx-camera
Company confidential.
This document is the property of Xenics. It may not be reproduced
–
completely or partially
–
or passed to a third
party without written permission from Xenics.
Xenics nv
T +32 16 38 99 00
Doc Ref: ENG-2019-UMN005
Ambachtenlaan 44
F +32 16 38 99 01
Issue: R003
BE-3001 Leuven
Belgium
www.xenics.com
Date: 15/05/2020
XF-104_03/20-12-2012
Page 68 of 73
58h
LineTriggerSoftware
WO
Software (Manual) line trigger generation
70h
TestpatternControl
RW
31..0
Internal custom pattern
0x800
08001
Bits #
Name
Function
15..0
Value
Pixel value
0
16
Moving
‘0’ False
‘1’ True
True
23..17
Do not use
27..24
Shift
Shift amount of the
pixel value
0
31..28
Selector
Select the pattern
0 : Fixed value
1 : vertical display
Vertic
al
displa
y
80h
uSecTimerLoad
WO
31..0
Load the timestamp
Bits #
Name
Function
0
uSecTimerLoad
Load the timestamp
31..0
Do not use
84h
uSecTimerLow
RW
31..0
Timestamp load value low word 32 bit
0
88h
uSecTimerHigh
RW
31..0
Timestamp load value high word 32 bit
0
204
IntegrationMode
RW
31..0
Readout mode used
Bits #
Name
Function
2..0
Reserved
3
Integration mode
Readout mode
0 : IWR
1 : ITR
0
6..4
Reserved
31..7
Do not use
2C8
ExposureTime
RW
25..0
Exposure time in µs
200
Table 6-9
Acquisition and trigger control registers
Image correction and processing control Registers
The base address for these registers is 8190
Byte
Offset
Name
Acces
s
Bits
Description
Default
value
0h
ImageProcessin
gControl
RW
31..0
Enable/Disable correction-processing
0x1
Bits #
Name
Function
0
RawMode
Enable/Disable
raw mode
‘0’ : Disable
‘1’ : Enable
True
1
GainEnable
Enable/Disable
fixed gain/offset
0: Disable fixed
gain/offset
1: Enable fixed
gain/offset
False
31..0
Do not use
4h
RW
31..0
Enable/disable correction
– processing blocks
0xF