![Xenics Manx-512 SQ CXP 130 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/xenics/manx-512-sq-cxp-130/manx-512-sq-cxp-130_user-manual_3289592019.webp)
User Manual
Manx-camera
Company confidential.
This document is the property of Xenics. It may not be reproduced
–
completely or partially
–
or passed to a third
party without written permission from Xenics.
Xenics nv
T +32 16 38 99 00
Doc Ref: ENG-2019-UMN005
Ambachtenlaan 44
F +32 16 38 99 01
Issue: R003
BE-3001 Leuven
Belgium
www.xenics.com
Date: 15/05/2020
XF-104_03/20-12-2012
Page 19 of 73
On the contrary, use the camera with a higher gain factor when the incoming signal is small.
Exposure time
Exposure time per line can be determined by the user using this function
Figure 5-3 Exposure time setting on Xeneth
Exposure time affects the line rate. Refer to frame rate calculator for details. (Ref 6)
Acquisition line time
Acquisition line time is the minimum time between 2 lines.
Figure 5-4 Acquisition line time setting in Xeneth
The actual line time, and hence line rate, is affected by the combination of exposure time
and acquisition line time.
When the exposure time is more than acquisition line time, the actual line time equals to the
exposure time