User Manual
Manx-camera
Company confidential.
This document is the property of Xenics. It may not be reproduced
–
completely or partially
–
or passed to a third
party without written permission from Xenics.
Xenics nv
T +32 16 38 99 00
Doc Ref: ENG-2019-UMN005
Ambachtenlaan 44
F +32 16 38 99 01
Issue: R003
BE-3001 Leuven
Belgium
www.xenics.com
Date: 15/05/2020
XF-104_03/20-12-2012
Page 22 of 73
Figure 5-8 Footer settings on Xeneth
The footer looks like this on the image.
Figure 5-9 Footer enable true
The footer is embedded in the last line of the frame when the footer information bit is enabled.
The first 64 pixels contain valid footer information and all other pixels have their current
values. The 16 data words are spread over the 8 most significant bits of the first 64 pixels.
Word
number
Value (16 bit)
Digital Video signal
1
Footer tag
0xF086
2
Line Status and
Readout mode
Bit number function
0
Odd Even line
1
Readout mode
IWR when value = b’0’
15 - 14
Do not use, value = b0000 00
3
Time stamp 1
64 bit time stamp in usecs since startup of
camera module
4
Time stamp 2
5
Time stamp 3
6
Time stamp 4
7
Frame number 1
32 bit frame number since startup of the
camera module
8
Frame number 2
9
Do not use
Not used, value = 0