Installation
2–4
975-0298-01-01
Table 2-1 contains the arrangements of wire colors to pin numbers for the
T568A standard.
•
Network terminators (Figure 2-3)—the Xanbus network must be
properly terminated at each end with male or female network
terminators to ensure the communication signal quality on the
network. If the network is not properly terminated, signal quality is
degraded and performance on the network is reduced. Permanent
configuration without terminators is not supported by Xantrex. The
System Control Panel ships with one male terminator already
installed. Depending on your network layout, this terminator may
need to be removed and inserted into another device elsewhere in the
network.
Figure 2-1
T568A Standard Wiring
Pin Number
Conductor Name
CAT 5 Cable Insulation Color
CAT 5e Cable Insulation Color
1
NET_S
White/Green
White/Orange
2
NET_S
Green
Orange
3
NET_C
White/Orange
White/Green
4
CAN_L
Blue
Blue
5
CAN_H
White/Blue
White/Blue
6
NET_C
Orange
Green
7
NET_S
White/Brown
White/Brown
8
NET_C
Brown
Brown
Figure 2-2
RJ-45 Connector
Pins:
8 7 6 5 4 3 2 1