Installation
2–10
975-0298-01-01
Multi-Drop Backbone Layout
To connect Xanbus cables to the System Control Panel:
1. Install one network connector for the System Control Panel and each
Xanbus-enabled device.
2. Connect a Xanbus cable from the nearest network connector to a
Xanbus network input in the System Control Panel.
3. Repeat the previous step for each additional Xanbus-enabled device.
4. Connect each network connector with a Xanbus cable as shown in
Figure 2-5.
5. Ensure the factory-supplied male network terminators (or a Xanbus
cable and female terminator) are inserted into the empty inputs in the
network connectors at the beginning and end of the network. There
should be no empty inputs in any of the network connectors.
Daisy Chain Layout
To connect Xanbus cables to the System Control Panel:
1. Connect the Xanbus cable (or two Xanbus cables, if the System
Control Panel is located between two Xanbus-enabled devices) to a
Xanbus network input in the System Control Panel.
2. Route and connect the cable(s) to the nearest Xanbus-enabled
device(s).
3. For additional devices, continue connecting cable as described above.
4. Ensure the factory-supplied male network terminators are inserted
into the empty inputs in the Xanbus-enabled devices at the beginning
and end of the network. When the network is completely connected,
there should be no empty network inputs in any Xanbus-enabled
device.
Содержание XW-SCP 865-1050
Страница 1: ...XW System Control Panel Owner s Guide Fault Warning System Control Panel II Standby ...
Страница 2: ......
Страница 3: ...XW System Control Panel Owner s Guide ...
Страница 30: ...2 16 ...
Страница 46: ...3 16 ...
Страница 56: ...4 10 ...
Страница 62: ...5 6 ...
Страница 66: ...A 4 ...
Страница 72: ...WA 6 ...
Страница 75: ......