SC
PI Co
mmand Re
fe
ren
ce
C–10
TM-XDOP-01XN
Table C-1
IEEE 488.2 Commands
Function
SCPI Commands
Description
Query
Clear Status
*CLS
[:]STATus[<channel>]:CLEAr
Clears the status data structures.
N/A
Standard Event
Status Enable Query
*ESE?
[:]STATus[<channel>]:STANdard:ENABle
Query the Standard Event Status
Enable register settings.
N/A
Standard Event
Status Enable
*ESE
[:]STATus[<channel>]:STANdard:ENABle <ESE-
word>
Set the Standard Event Status
Enable Register bits.
N/A
Standard Event
Status Register
Query
*ESR?
[:]STATus[<channel>]:STANDard[:EVENt]?
Query Standard Event Status
Register.
N/A
Identification Query
*IDN?
[:]SYSTem[<channel>]:IDENtify?
Query identification string.
(Manufacturer’s information.)
N/A
Individual Status
Query
*IST?
Reads the current state of the
IEEE 488.1 defined "ist" local
message in the device
N/A
Operation Complete
Command
*OPC
Causes the device to generate the
operation complete message in the
Standard Event Status register
when all pending selected device
operations have finished
N/A
Query Operation
Complete
Command
*OPC?
Place and ASCII character “1”
into the output queue when all
pending operations have been
finished. See IEEE 488.2-1992
section 12.5.3.
N/A
Option
Identification Query
*OPT?
[:]SYSTem[<channel>]:OPTIon
Identify reportable device options
N/A
Parallel Poll Enable
Register Query
*PRE?
Query the Parallel Poll Enable
Register setting
N/A
Parallel Poll Enable
Register Command
*PRE <status-enable>
Sets the Parallel Poll Enable
Register bits. See IEEE 488.2
section 11.6 for details.
N/A
TM-XDOP-01XN.book Page 10 Monday, July 17, 2006 11:19 AM
Содержание XDC 10-1200
Страница 2: ......
Страница 3: ...XDC 6000 Watt and 12000 Watt Series Digital Programmable Power Supply Operating Manual ...
Страница 8: ...vi ...
Страница 12: ...x ...
Страница 22: ...xx ...
Страница 24: ...xxii ...
Страница 39: ...2 Installation Chapter 2 explains how to mount and wire the XDC and also how to perform basic functional tests ...
Страница 43: ...Location Mounting and Ventilation TM XDOP 01XN 2 5 Figure 2 2 Unpacking the Power Supply 6000 Watt shown ...
Страница 48: ...Installation 2 10 TM XDOP 01XN Figure 2 5 Attaching the AC Input Wires for 6000 Watt units ...
Страница 59: ...Load Connections TM XDOP 01XN 2 21 Figure 2 9 Output for 12000 Watt units low and medium voltage ...
Страница 61: ...Load Connections TM XDOP 01XN 2 23 Figure 2 11 Output for 12000 Watt units high voltage 300 600V ...
Страница 114: ...Operation 3 52 TM XDOP 01XN ...
Страница 208: ...A 16 ...
Страница 224: ...B 16 ...
Страница 259: ...D Error Messages Appendix D lists all the error codes and their meanings ...
Страница 268: ...D 10 ...
Страница 269: ...E GPIB Appendix E describes the General Purpose Interface Bus GPIB commands and lines supported by this model ...
Страница 283: ......