SC
PI Co
mmand Re
fe
ren
ce
C–30
TM-XDOP-01XN
Program selected
sequence step
voltage
[:]PROGram[<channel>][:SELected]:STEP<step_numb
er>:VOLTage <voltage>
Edit/program step voltage of
selected sequence
Yes
Program selected
sequence step
power
[:]PROGram[<channel>][:SELected]:STEP<step_numb
er>:POWer <power>
Edit/program step power of
selected sequence
Yes
Program selected
step OVP
[:]PROGram[<channel>][:SELected]:STEP
<step_number>:OVP <OVP_level>
Edit/program step OVP level of
selected sequence
Yes
Program selected
sequence step time
[:]PROGram[<channel>][:SELected]:STEP<step_numb
er>:DWELl {<step_time>|TRIG}
Edit/program step time or
triggering of selected sequence
Yes
Program selected
sequence trigger
source
[:]PROGram[<channel>][:SELected]:TRIGger:SOURce
{BUS|MANual|EXTernal|IMMediate}
Edit/program trigger source of
selected sequence
Yes
Program selected
sequence end action
[:]PROGram[<channel>][:SELected]:REPeat
{<sequence_count>|ONCE|FORever|INFinity}
Edit/program end action of
selected sequence
Yes
Read specific
sequence number of
steps
[:]PROGram[<channel>]:SEQuence<sequence_number>
:STEP:COUNt?
Read number of programmed
steps in specific sequence
Yes
Delete a specific
sequence
[:]PROGram[<channel>]:SEQuence<sequence_number>
:
DELete
The specific sequence is deleted
N/A
Delete specific
sequence step
[:]PROGram[<channel>]:SEQuence<sequence_number>
:STEP<step_number>:DELete
Delete a specific sequence step
N/A
Edit specific
sequence step
[:]PROGram[<channel>]:SEQuence<sequence_number>
:STEP <step_number>[:EDIT]
[[[[[<voltage>],<current>],<power>],<OVP_level>
],{<time>|TRIG}]
Edit a specific sequence step
Yes
Insert step into
specific sequence
[:]PROGram[<channel>]:SEQuence<sequence_number>
:STEP<step_number>:INSert
<voltage>,<current>,<power>,<OVP_level>,{<step_
time>|TRIG}
Insert a step into a specific
sequence
N/A
Table C-14
Auto Sequence Commands
Function
SCPI Command
Description
Query
TM-XDOP-01XN.book Page 30 Monday, July 17, 2006 11:19 AM
Содержание XDC 10-1200
Страница 2: ......
Страница 3: ...XDC 6000 Watt and 12000 Watt Series Digital Programmable Power Supply Operating Manual ...
Страница 8: ...vi ...
Страница 12: ...x ...
Страница 22: ...xx ...
Страница 24: ...xxii ...
Страница 39: ...2 Installation Chapter 2 explains how to mount and wire the XDC and also how to perform basic functional tests ...
Страница 43: ...Location Mounting and Ventilation TM XDOP 01XN 2 5 Figure 2 2 Unpacking the Power Supply 6000 Watt shown ...
Страница 48: ...Installation 2 10 TM XDOP 01XN Figure 2 5 Attaching the AC Input Wires for 6000 Watt units ...
Страница 59: ...Load Connections TM XDOP 01XN 2 21 Figure 2 9 Output for 12000 Watt units low and medium voltage ...
Страница 61: ...Load Connections TM XDOP 01XN 2 23 Figure 2 11 Output for 12000 Watt units high voltage 300 600V ...
Страница 114: ...Operation 3 52 TM XDOP 01XN ...
Страница 208: ...A 16 ...
Страница 224: ...B 16 ...
Страница 259: ...D Error Messages Appendix D lists all the error codes and their meanings ...
Страница 268: ...D 10 ...
Страница 269: ...E GPIB Appendix E describes the General Purpose Interface Bus GPIB commands and lines supported by this model ...
Страница 283: ......