Power Supply Operation
TM-XDOP-01XN
3–39
Deleting a Sequence Step
This option allows you to delete a particular step in a sequence that has already
been programmed.
To delete a step in a programmed sequence:
Step #
Do This
You Will See
1
ERROR MSGS
2
6 times or
.
AUTO SEQ PGM
3
Sequence 1
4
or
. Use the scroll keys to
select a sequence to work with.
Sequence #
5
Edit
Sequence
6
Step 1
7
or
. Use the scroll keys to
select the step to delete.
Step #
8
Edit Step
9
or
. Use the scroll keys to
select the Delete Step option.
Delete Step
10
Step ## Deleted
11
Step ##
12
Step has now been deleted. Select another step
to work with or escape by pressing
.
MENU
MENU
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
EXIT
TM-XDOP-01XN.book Page 39 Monday, July 17, 2006 11:19 AM
Содержание XDC 10-1200
Страница 2: ......
Страница 3: ...XDC 6000 Watt and 12000 Watt Series Digital Programmable Power Supply Operating Manual ...
Страница 8: ...vi ...
Страница 12: ...x ...
Страница 22: ...xx ...
Страница 24: ...xxii ...
Страница 39: ...2 Installation Chapter 2 explains how to mount and wire the XDC and also how to perform basic functional tests ...
Страница 43: ...Location Mounting and Ventilation TM XDOP 01XN 2 5 Figure 2 2 Unpacking the Power Supply 6000 Watt shown ...
Страница 48: ...Installation 2 10 TM XDOP 01XN Figure 2 5 Attaching the AC Input Wires for 6000 Watt units ...
Страница 59: ...Load Connections TM XDOP 01XN 2 21 Figure 2 9 Output for 12000 Watt units low and medium voltage ...
Страница 61: ...Load Connections TM XDOP 01XN 2 23 Figure 2 11 Output for 12000 Watt units high voltage 300 600V ...
Страница 114: ...Operation 3 52 TM XDOP 01XN ...
Страница 208: ...A 16 ...
Страница 224: ...B 16 ...
Страница 259: ...D Error Messages Appendix D lists all the error codes and their meanings ...
Страница 268: ...D 10 ...
Страница 269: ...E GPIB Appendix E describes the General Purpose Interface Bus GPIB commands and lines supported by this model ...
Страница 283: ......