About The XDC Power Supply
1–12
TM-XDOP-01XN
Overview of Operation
Power ON
Power ON describes the period between the time the AC power is turned ON and
the time the power supply is ready for normal operation. Each supply comes with
a series of factory default settings that may be in effect at the conclusion of the
Power ON period. These include:
•
Output OFF:
No current is sent to the DC output connections. You must
press
Out ON/OFF
to activate the supply output.
•
Voltage 0V:
The Voltage setpoint is zero.
•
Current 0A:
The Current setpoint is zero.
•
Local mode operation
The output state depends on the Power ON output setting. You can customize the
Power ON settings to suit your needs. See “Configure Power ON Settings” on
page 3–29 for more information.
Control Modes
One local method and 4 remote methods are available for controlling the power
supply:
•
Local Mode:
Where the user operates the menu keypad and knobs
•
RS-232:
Where the user operates the supply remotely through a serial port
connection (standard feature).
•
GPIB:
Where the user operates the supply remotely through the faster
General Purpose Interface Bus. The GPIB bus follows the IEEE 488.2
standard and is an optional feature of this power supply.
•
Multichannel:
Where the user operates the supply remotely through the
optional multichannel link between 2 or more (up to 50) power supplies
(optional feature).
•
Analog:
Where the user operates the supply remotely through the isolated
analog programming and readback port (standard feature). Three options are
available:
•
Analog V and I
•
Analog V
•
Analog I
Each of these methods is referred to as a control mode.
TM-XDOP-01XN.book Page 12 Monday, July 17, 2006 11:19 AM
Содержание XDC 10-1200
Страница 2: ......
Страница 3: ...XDC 6000 Watt and 12000 Watt Series Digital Programmable Power Supply Operating Manual ...
Страница 8: ...vi ...
Страница 12: ...x ...
Страница 22: ...xx ...
Страница 24: ...xxii ...
Страница 39: ...2 Installation Chapter 2 explains how to mount and wire the XDC and also how to perform basic functional tests ...
Страница 43: ...Location Mounting and Ventilation TM XDOP 01XN 2 5 Figure 2 2 Unpacking the Power Supply 6000 Watt shown ...
Страница 48: ...Installation 2 10 TM XDOP 01XN Figure 2 5 Attaching the AC Input Wires for 6000 Watt units ...
Страница 59: ...Load Connections TM XDOP 01XN 2 21 Figure 2 9 Output for 12000 Watt units low and medium voltage ...
Страница 61: ...Load Connections TM XDOP 01XN 2 23 Figure 2 11 Output for 12000 Watt units high voltage 300 600V ...
Страница 114: ...Operation 3 52 TM XDOP 01XN ...
Страница 208: ...A 16 ...
Страница 224: ...B 16 ...
Страница 259: ...D Error Messages Appendix D lists all the error codes and their meanings ...
Страница 268: ...D 10 ...
Страница 269: ...E GPIB Appendix E describes the General Purpose Interface Bus GPIB commands and lines supported by this model ...
Страница 283: ......