Troubleshooting
9–4
976-0043-01-02
Battery Charger Troubleshooting
If the red ERROR LED illuminates on the ICM display, see
“05 Error
Causes Menu” on page 8–25
to determine the cause of the error condition.
Then use the solutions below to resolve the situation.
Problem
Possible Cause
Solution
AC1 LED is flashing, but
will not start charging
(allow 40 seconds to
synchronize).
Battery voltage is below
the 22B Low Xfer (BX)
VDC setting.
You are outside of the
21 Grid Usage timer
period.
Check for the correct AC voltage or frequency at the
AC input terminal. If it is normal:
1) Check to see if the BX Mode is enabled. The AC
input is not allowed to synchronize and pass-through
unless the battery voltage reaches the 22B Low Xfer
(BX) VDC setting.
2) Check to see if the 21 Grid Usage timer (21B and
21C) is enabled and that you are outside of the
21 Grid Usage timer period. The AC is not allowed
to synchronize and charge unless you are within the
21 Grid Usage timer period.
AC1 or AC2 LED is
flashing, but will not start
charging
(allow 40 seconds to
synchronize).
AC frequency at the AC
input terminal may be
out-of-tolerance (too high
or low) or the AC voltage
may be outside the
13C Input Upper Limit
VAC or 13D Input
Lower Limit VAC
settings.
Check for the correct AC voltage or frequency at the
AC input terminal. If the AC source is a generator,
adjust the AC voltage or frequency accordingly.
AC1 or AC2 LED is
flashing and repeatedly
connects and disconnects
to the source.
AC frequency at the AC
input terminal may be
out-of-tolerance (too high
or low) or the AC voltage
may be outside the
13C Input Upper
Limit VAC or 13D Input
Lower Limit VAC
settings.
Or the inverter circuit
breaker has opened.
Check for the correct AC voltage or frequency at the
AC input terminal. If the AC source is a generator,
adjust the AC voltage or frequency accordingly.
If the circuit breaker is open, press it back in to reset
it.
If circuit breaker on the inverter is not open, the
inverter may need to be serviced.
Содержание SW Plus 2524
Страница 2: ......
Страница 3: ...Sine Wave Plus Inverter Charger Owner s Manual...
Страница 82: ...2 48...
Страница 101: ...DC Wiring 976 0043 01 02 3 19 Figure 3 9 BTS RJ11 Port Location and Installation BTS RJ11 Port DC End of the Inverter...
Страница 105: ...DC Wiring 976 0043 01 02 3 23 Figure 3 13 DC Connections to a Single Inverter...
Страница 107: ...DC Wiring 976 0043 01 02 3 25 Figure 3 14 DC Connections to Dual Inverters...
Страница 126: ...3 44...
Страница 127: ...4 Functional Test Chapter 4 Functional Test explains how to conduct a functional test of the inverter...
Страница 132: ...4 6...
Страница 141: ...Menu Map 976 0043 01 02 5 9 Figure 5 10 User Menu Map Part 2...
Страница 143: ...Menu Map 976 0043 01 02 5 11 Figure 5 12 Basic Setup Menu Map Part 2...
Страница 145: ...Menu Map 976 0043 01 02 5 13 Figure 5 14 Advanced Setup Menu Map Part 2...
Страница 146: ...Navigation 5 14 976 0043 01 02 Figure 5 15 Complete User Menu Map...
Страница 147: ...Menu Map 976 0043 01 02 5 15 Figure 5 16 Complete Basic Setup Menu Map...
Страница 148: ...Navigation 5 16 976 0043 01 02 Figure 5 17 Complete Advanced Setup Menu Map...
Страница 200: ...Advanced Setup 7 22 976 0043 01 02 Figure 7 3 Relay 11 Wiring Example to Dual Inverters with Cooldown selected...
Страница 250: ...8 32...
Страница 274: ...A 16...
Страница 308: ...C 18...
Страница 312: ...D 4...
Страница 316: ...E 4...
Страница 338: ...I 6...
Страница 342: ...Index IX 4 976 0043 01 02...
Страница 343: ......