User Menu Settings
976-0043-01-02
B–3
Ph 1-800-446-6180
www.xantrex.com
Press reset for factory defaults
Press to refresh the LCD display.
04 Meters Menu
See
“04 Meters Menu” on page 8–22
for details.
04A Battery Actual VDC
13.2 to 35.5
Read Only
20.0 to 71.0
Read Only
04B Battery Comp VDC
13.2 to 35.5
Read Only
20.0 to 71.0
Read Only
04C Inv/Chr Amps AC
-63 to 63
Read Only
-63 to 63
Read Only
04D Input Amps AC
00 to 63
Read Only
00 to 63
Read Only
04E Load Amps AC
00 to 63
Read Only
00 to 63
Read Only
04F Inverter Volts AC
00 to 163
Read Only
00 to 163
Read Only
04G Grid (AC1) Volts AC
00 to 163
Read Only
00 to163
Read Only
04H Gen (AC2) Volts AC
00 to 163
Read Only
00 to 163
Read Only
04I Frequency Hertz
52 to 68
Read Only
52 to 68
Read Only
04J Max Bulk/EQ Time h:m
00:00 to
23:50
Read Only
00:00 to
23:50
Read Only
04K Battery Temp Degrees C
-28 to 60, OL Read Only
-28 to 60, OL Read Only
04L Fan Speed
00, 01, 02,
03, 04
Read Only
00, 01, 02,
03, 04
Read Only
05 Error Causes Menu
See
“05 Error Causes Menu” on page 8–25
for details.
05A Over Current
NO YES
Read Only
NO YES
Read Only
05B Transformer overtemp
NO YES
Read Only
NO YES
Read Only
05C Heatsink overtemp
NO YES
Read Only
NO YES
Read Only
05D Low Battery Voltage
NO YES
Read Only
NO YES
Read Only
05E High Battery Voltage
NO YES
Read Only
NO YES
Read Only
05F External err (stacked)
NO YES
Read Only
NO YES
Read Only
05G Input Relay Failure
NO YES
Read Only
NO YES
Read Only
05H Gen Failed to Start
NO YES
Read Only
NO YES
Read Only
05I Gen Stopped due to V/F
NO YES
Read Only
NO YES
Read Only
Table B-1
User Menu Default and User Settings
User Menus
Sine Wave Plus
2524 and 4024
Sine Wave Plus
2548, 4048, and 5548
User
Settings
Range/
Display
Default
Settings
Range/
Display
Default
Settings
Содержание SW Plus 2524
Страница 2: ......
Страница 3: ...Sine Wave Plus Inverter Charger Owner s Manual...
Страница 82: ...2 48...
Страница 101: ...DC Wiring 976 0043 01 02 3 19 Figure 3 9 BTS RJ11 Port Location and Installation BTS RJ11 Port DC End of the Inverter...
Страница 105: ...DC Wiring 976 0043 01 02 3 23 Figure 3 13 DC Connections to a Single Inverter...
Страница 107: ...DC Wiring 976 0043 01 02 3 25 Figure 3 14 DC Connections to Dual Inverters...
Страница 126: ...3 44...
Страница 127: ...4 Functional Test Chapter 4 Functional Test explains how to conduct a functional test of the inverter...
Страница 132: ...4 6...
Страница 141: ...Menu Map 976 0043 01 02 5 9 Figure 5 10 User Menu Map Part 2...
Страница 143: ...Menu Map 976 0043 01 02 5 11 Figure 5 12 Basic Setup Menu Map Part 2...
Страница 145: ...Menu Map 976 0043 01 02 5 13 Figure 5 14 Advanced Setup Menu Map Part 2...
Страница 146: ...Navigation 5 14 976 0043 01 02 Figure 5 15 Complete User Menu Map...
Страница 147: ...Menu Map 976 0043 01 02 5 15 Figure 5 16 Complete Basic Setup Menu Map...
Страница 148: ...Navigation 5 16 976 0043 01 02 Figure 5 17 Complete Advanced Setup Menu Map...
Страница 200: ...Advanced Setup 7 22 976 0043 01 02 Figure 7 3 Relay 11 Wiring Example to Dual Inverters with Cooldown selected...
Страница 250: ...8 32...
Страница 274: ...A 16...
Страница 308: ...C 18...
Страница 312: ...D 4...
Страница 316: ...E 4...
Страница 338: ...I 6...
Страница 342: ...Index IX 4 976 0043 01 02...
Страница 343: ......