![Worcester GR2300iW C Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/worcester/gr2300iw-c/gr2300iw-c_installation-and-maintenance-instructions-manual_996431021.webp)
Pre-Installation
21
Greenstar 2000 – 6 721 820 552 (2021/02)
High level horizontal flue
Fig. 20 Horizontal flue option
• Flue length [L] (initial bend included in length calculation)
– Maximum flue length as stated in "Horizontal maximum flue
High level horizontal flue with additional 90° elbow
Fig. 21 Horizontal flue option
• Flue length [L] (initial bend included in length calculation)
– Maximum flue length as stated in "Horizontal maximum flue
lengths" minus the 90° bend equivalent straight flue length as
stated in Table 16 "Effective length of bends".
High level horizontal flue with additional 90° elbows
Fig. 22 Horizontal flue option
• Flue length [L] (initial bend included in length calculation)
– Maximum flue length as stated in "Horizontal maximum flue
lengths" minus 2 x 90° bends equivalent straight flue length as
stated in Table 16 "Effective length of bends".
Vertical balanced flue assembly
Fig. 23 Vertical flue option
• Flue length [L]
– Maximum flue length as stated in "Vertical maximum flue
Vertical balanced flue with 90° elbow offset
Fig. 24 Vertical flue option
• Flue length [L]
– Maximum flue length as stated in "Vertical maximum flue lengths"
minus 2 x 90° bends equivalent straight flue length as stated in
Table 16 "Effective length of bends".
Vertical balanced flue with 45° elbow offset
Fig. 25 Vertical flue option
• Flue length [L]
– Maximum flue length as stated in "Vertical maximum flue lengths"
minus 2 x 45° bends equivalent straight flue length as stated in
Table 16 "Effective length of bends".
0010015196-001
0010015197-001
0010015198-001
0010015199-001
A = 300 mm
B = 500 mm
0010015200-001
A = 300 mm
B = 500 mm
0010015201-001
A = 300 mm
B = 500 mm