Pre-Installation
Greenstar 2000 – 6 721 820 552 (2021/02)
18
4.3.3
Appliance clearances
• The following details cover the installation, service and maintenance
clearances for the appliance.
CAUTION
Risk of damage to appliance or property
The appliance will overheat if the clearance space around the appliance
is restricted by objects.
▶ Do not restrict this space with the addition of cupboards, shelves etc.
next to or around the appliance.
▶ Do not store any combustible materials on or next to the appliance,
such as clothes, towels, paper or plastic bags.
Fig. 11 Appliance minimum clearances
Table 12 Appliance minimum clearances
Reduced front maintenance minimum clearances
The front servicing clearance for this appliance can be reduced to
450mm.
For installations with a front servicing clearance less than 600mm
(minimum of 450mm), the following additional criteria must be
achieved.
• The bottom of the appliance case must be between 1000mm and
1500mm from the floor.
• There must be at least 450mm clearance in front of the appliance to
floor level. Anything sited below the appliance must not protrude into
this clear space.
• There must be at least 200mm clearance to any structure which is
sited below the appliance.
• There must be at least 300mm clear space to either the left hand or
right hand side of the appliance. This clear space must be from the
required clear height above the appliance to floor level.
– This clearance will not apply if the appliance is sited within
300mm of a door way and the door frame is the only obstruction.
Minimum clearances must be observed to any obstruction/ surface,
(dark shaded areas, figures 12 and 13).
Fig. 12 Reduced front maintenance clearances - Side view
[A]
Appliance.
[1]
Above appliance - Same clearance required as for standard
clearances of 60/100 flue or 80/125mm flue.
[2]
In front of appliance - Minimum 450mm.
[3]
Bottom of appliance to the floor - 1,000 - 1,500mm.
[4]
Below appliance - 200mm
Minimum clearances
Description
Dimensions (mm)
X
Appliance width
400
Y
Appliance height
724
1)
1) Side panel height = 710mm
Z
Appliance depth
300
Installation/Maintenance
1
Overall clearance height
1094/1134
2)
2) Height for either 60/100 flue or 80/125 flue
2
Overall clearance depth
900
3)
3) This can be reduced (refer to Reduced front maintenance minimum clearances).
3
In front of appliance
4
Overall clearance width
410
5
Above the appliance
6
Either side of appliance
5
7
Below the appliance
200
8
Compartment depth
320
4)
4) Clearance to a combustible material
9
Appliance to removable door
20
0010012940-001
0010031674-001
1
2
2
4
3