Greenstar 2000 – 6 721 820 552 (2021/02)
Legend to figure 3:
[1]
Inspection aperture
[2]
Flue connection
[3]
Heating block temperature limiter
[4]
Electrode set
[5]
Ignition transformer
[6]
Control pressure test point
[7]
Gas-air mixing chamber
[8]
Heating block
[9]
Gas valve
[10] Condensate sump
[11] Cover for inspection aperture
[12] Diverter valve motor
[13] Diverter valve
[14] Automatic air vent
[15] Heating pump
[16] Pump speed adjuster and LED indicator
[17] Pressure relief valve (heating circuit)
[18] Plate heat exchanger
[19] KEY accessory housing (wireless gateway)
[20] Pressure gauge
[21] Position for code plug (KIM)
[22] Control unit
[23] DHW temperature sensor
[24] Pressure switch
[25] Flow turbine
[26] Fuse (replacement)
[27] Condensate trap
[28] Data plate
[29] Condensate trap locking mechanism
[30] Gas supply pressure test point
[31] Flue gas temperature limiter
[32] Flow temperature sensor
[33] Schrader valve
[34] Expansion vessel
[35] Fan
[36] Air-gas manifold with non-return valve
[37] Heating flow
[38] Flow temperature sensor at heating
[39] Bracket
[40] Combustion air intake
3.7
Product data for energy consumption
The product data on energy consumption can be found in the operating
instructions for the user.
3.8
Standard accessories
3.8.1
Appliance accessories
Table 5 Appliance accessories
3.8.2
Programmer/timer accessories
The programmers/timers listed can be used with the appliances stated
on the front of this manual.
Table 6 Control accessories
Bosch EasyControl smart control system
Table 7 EasyControl accessories
Basic weather compensation sensor
Outdoor weather sensor (to activate on-board simple Weather
Compensation).
Table 8 Control accessories
The outdoor weather sensor is supplied with the Sense II. It is optional
with the II RF. Weather compensation is available with the
EasyControl without the need for a physical outdoor sensor, however, it
can improve control accuracy for installations in isolated micro-climates
or highly sheltered locations such as valleys.
Part number
Description
7 733 600 266
Greenstar System filter (22mm mini)
7 733 600 236
Greenstar System filter (22mm)
7 733 600 237
Greenstar System filter (28mm)
7 733 600 476
Greenstar System filter brass (22mm)
7 716 192 746
Worcester CondenseSure
7 716 192 610
Keyless filling link kit
7 733 600 091
Heat exchanger cleaning kit
7 736 902 107
Low NOx code plug kit 25kW
7 736 902 108
Low NOx code plug kit 30kW
7 736 900 525
Greenstar Xtra FGHR
Part number
Description
7 733 600 332
MT20 mechanical timer
7 733 600 333
MT20RF mechanical thermostat
7 738 110 054
Sense I
7 738 111 064
Sense II (including weather sensor)
1)
1) Preheat time control available.
7 738 112 324
II RF
7 738 112 338
stat RF
2)
2) Must be used with an external proprietary 230V timer.
Part number
Description
7 736 701 341
EasyControl (white)
1)
1) Preheat time control available.
7 736 701 392
EasyControl (black)
7 738 112 351
EasyControl RF Key
7 736 701 555
EasyControl TRV set (white)
7 736 701 556
EasyControl TRV set (black)
8 750 000 270
EasyConstrol smart TRV (individual)
Part number
Description
7 716 192 764
Outdoor weather sensor