Settings in the service menu
Greenstar 2000 – 6 721 820 552 (2021/02)
54
8.2
Service functions overview
8.2.1
Menu 1
▶ Press the
(
key and
*
key at the same time until
L.1
appears.
▶ To confirm the selection: press
OK
key.
▶ Selecting and setting the service function.
Table 25 Menu 1: display of information
8.2.2
Menu 2
▶ Press the
(
key and
*
key at the same time until
L.1
appears.
▶ Press arrow key
until
L.2
is displayed.
▶ To confirm the selection: press
OK
key.
▶ Selecting and setting the service function.
The basic settings are depicted as
highlighted
in the following table.
Table 26 Menu 2: hydraulic settings
Service function
Unit
Further information
1-A1 Current operating status
Status code,
Section 11.2
1-A2 Current fault
Error code,
Section 11.2
1-A3 Upper limit of the maximum heat output
%
The maximum heat output can be decreased via the service function
3-b1.
1-A4 Upper limit of the maximum DHW output
%
The maximum DHW output can be decreased via the service
function 3-C1.
1-A5 Temperature at flow temperature sensor
°C
–
1-A6 Set flow temperature
°C
–
1-b2 Current turbine flow rate
l/min
–
1-b3 Current DHW temperature
°C
–
1-b4 Current DHW outlet temperature
°C
–
1-b5 Current temperature at the cylinder
°C
–
1-b7 Set DHW temperature
°C
–
1-b8 Current thermal output as a % of the maximum rated heat output
in heating mode
%
During DHW heating, values greater than 100 % may be displayed.
1-C1 Ionisation current
A
• Minimum burner operation or greater: ≥ 2
A = OK,
< 2
A = faulty
• While the burner is switched off: < 2
A = OK, ≥ 2
A = faulty
1-C2 Current pump output as % of rated pump output
–
1-C4 Current outside temperature with outside temperature sensor
connected
°C
–
1-C5 Temperature at the solar buffer cylinder
°C
Only displayed when a solar module is connected.
1-C6 Operating pressure
bar
–
1-d1 Collector temperature
°C
Only displayed when a solar module is connected.
1-d2 Temperature at the solar buffer cylinder (bottom)
°C
Only displayed when a solar module is connected.
1-d3 Solar pump
%
Only displayed when a solar module is connected.
1-d4 Solar unit fault
Only displayed when a solar module is connected.
Error code
1-E1 Software version of the control panel (main version)
–
1-E2 Software version of the control panel (secondary version)
–
1-E3 Coding plug number
–
1-E4 Coding plug version
–
1-EA Software version of device electronics (main version)
–
1-Eb Software version of device electronics (secondary version)
–
Service function
Settings/adjustment range
Remark/restriction
2-A1 Low-loss header
•
0
: no low loss header installed
• 1: (not available)
• 2: low loss header connected to the module
This setting defines where the sensor of the low
loss header is connected.