19
3061490_0709
Power supply
Isolate the condensing boiler from the pow
-
er supply prior to changing a fuse. The ON/
OFF switch on the boiler does not provide
separation from the power supply.
Danger through 'live' electrical compo
-
nents. Never touch electrical components
or contacts as long as the condensing
boiler has not been isolated from the power
supply.
Risk to life!
Changing a fuse
Fig.: Pivot the control unit forward; terminal box cover open
Fuse
Fig.: Connection output A1
Fig.: Blue plug, cylinder sensor connection
DHW sensor connection
- When a cylinder is to be connected, the blue socket
of the cylinder sensor must be connected to the blue
plug of the control unit.
- Observe the cylinder installation instructions.
Blue plug
Fig.: Connection DHW circulation pump/external accesso
-
ries
Connection DHW circulation pump/
external accessories (230 V AC)
Insert the cable glands into the terminal box. Insert and
secure the cable through the cable gland.
Connect the DHW circulation pump 230 V AC, which
is part of the Wolf accessory range, to terminals L1, N
and
.
Connection output A1
(230 V AC; 200 VA)
Insert the cable glands into the terminal box. Insert and
secure the connecting cable through the cable gland.
Connect the cable to terminals L1, N and
.
The parameters for output A1 are described in the table
on the following page.
Netz
Z
A1
N
N
N
L1
L1
L1
L1
L1
L1
N
N
N
3
MAINS
Netz
Z
A1
N
N
N
L1
L1
L1
L1
L1
L1
N
N
N
3
MAINS