INCOMING SIGNALS FROM THE DOOR CONTROLLER
Signal
Connector Pins
Contact type & normal state
Note
Opening control Ka
(coming from the Main Lift
Controller)
Connector pins
5-15
These connections require dry
(voltage free) contacts (contact
open when inactive)
When the Door Controller is
installed on a Front & Rear entrance
car, it is important that the opening
and closing commands have no
common contacts between the two
doors.
Shielded, Grounded Wire Highly
Recommended
Closing control Kc
(coming from the Main Lift
Controller)
Connector pins
3-15
These connections require dry
(voltage free) contacts (contact
open when inactive)
Forced closing control at low speed
Kb
Connector pins
15-22
These connections require dry
(voltage free) contacts (contact
open when inactive)
The main lift controller may
signal the forced closing when the
photocell (or similar device) shall be
made inoperative due to a failure, or
after several door closing failures.
Re-opening control Kn
Connector pins
15-23
These connections require dry
(voltage free) contacts (both logics
available)
Fire-Fighting Contact Kff
Connector pins
15-39
These connections require dry
(voltage free) contacts (contact
open when inactive)
Contact K2TB
Connector pins
15-41
These connections require dry
(voltage free) contacts (contact
open when inactive)
This signal allows the door
controller to recognize different
door opening widths in the same
lift installation.
Given this signal, the opening and
closing operations are carried out
referring to an alternative TB (door
width recorded by an additional
self-learning cycle).
Encoder signals
Connector RJ45 (A)
Factory prewired connector
Contact KEOD
Connector pins
15-40
These connections require dry
(voltage free) contacts (contact
open when inactive)
This connection is to signal the use
of the Sematic E.O.D. Emergency
Opening Device to the Door
controller
Handset (Optional)
Connector RJ45 (B)
Auxliary contact Kaux
Connector pins
15-42
These connections require dry
(voltage free) contacts (contact
open when inactive)
Not yet implemented
Note
: Sematic Drive System
©
controller may be used also with incoming signal from the Main Lift Controller with voltage range between
6 and 24 Vdc.
To use this feature:
•
Remove the shunt between 37-38 connector pins
•
Connect the 38 connector pin at the 0V DC external incoming signal Power supply