13
www
.wittur
.com
© WI
TTUR • All rights r
eser
ved
PM.2.004921.EN - 808-001-000 SDS
©
rel 3 · Edition 22 July 2020
Drive - Instruction Manual
3 GENERAL FEATURES
3.1 TECHNICAL INFORMATION SEMATIC DRIVE SYSTEM
©
(DC-PWM)
MAIN SUPPLY VOLTAGE
90-290 Vac (115 V-20%, 230V+26%), 50-60 Hz
TYPICAL POWER CONSUMPTION
200 VA
PEAK POWER CONSUMPTION
300 VA
MOTOR OVERLOAD PROTECTION
@In <15 minutes
@2In <3 minutes
OPERATIONAL TEMPERATURE RANGE
from -10°C to +60°C
HUMIDITY
non-condensing between 20% and 80%
PROTECTION
rapid cartridge fuse [5x20, 4 A, R/C JDYX2]
battery fuse [5x20, 8 A, R/C JDYX2]
PERFORMANCE SPEED
separately adjustable for opening and closing
REVERSAL SENSITIVITY
Variable, only operational on door closing cycle
Suitable for use on a circuit capable of delivering not more than 5000 Arms, symmetrical Amperes, 240 V AC maximum
3.2 SEMATIC DRIVE SYSTEM
©
DOOR CONTROLLER (DC-PWM)
1.
Power ON button
2.
Power OFF button
3.
Display
4.
Manual mode buttons
5.
RJ45 Connection port (Handset)
6.
6 poles motor and auxiliary EOD battery power supply connector (cod. E066AARX-05)
7.
RJ45 Connection port (Motor optical Encoder)
8.
4 poles detector / photocells connector (cod. E066AARX-06)
9.
6 poles Main Lift Controller signals connector (cod. E066AARX-03)
10.
6 poles Main Lift Controller signals connector (cod. E066AARX-04)
11.
10 poles Main Lift Controller signals connector (cod. E066AARX-07)