5.3 PROGRAMMING MODE “PROG”
•
When the Door Controller is working in “programming mode” the “PROG” red led is on whereas the other two red leds are off.
•
Press contemporaneously Key 1 and Key 4 for few seconds to enter the programming mode. The display on the Door Controller will
show “P” and “00” flashing alternately.
•
When the Door Controller is in the programming mode, all signals coming from the main lift controller and from the external
devices (barriers, photocells,…) are ignored.
•
The parameter to be modified is selected by means of the increasing and decreasing KEYs, respectively the buttons 2 and 3; this
parameter is then confirmed by pushing the key 1, ENTER.
•
After confirming the parameter to be modified, the display shows the relevant numeric value.
•
Modify the chosen parameter using the key 2, increase, and 3, decrease, and confirm the changes by pressing key 1 ENTER.
•
At the end of the necessary configurations, using the key 4 press to select the required operating mode (manual “MAN” or automatic
“AUTO”).
5.4 VERIFY THE CORRECT WORKING OF THE CONTROLLER SDS
In order to verify if the controller is broken or not please follow the instruction below:
INSTRUCTIONS:
1.
Remove all the connections to the controller including the power supply.
2.
Verify the controller power supply fuse.
Note
: Eventually replace the fuse.
3.
Connect only the power supply cable
4.
Verify, that after switching ON the controller by the key ON, the controller disply will light
“|- -|”
after 5 seconds
5.
Switch OFF the controller and connect the motor and the encoder
6.
Switch ON and verify the display lighting
7.
Press key 4 to enter in MAN mode (led MAN switch on).
8.
Press key 2 and 3 to verify the partial motor movement (partial opening and closing movement).
Note
: In case of alarm or loss of
movement try to connect another motor with encoder (only the connection, do not replace it initially on the door and repeat from
point 5 to point 8. If the new motor works correctly replace the motor on the door.
CHECK: CONTROLLER NOT DEFECTIVE
5.5 RESET SPEED PROFILE PROCEDURE
9.
Verify that after switching ON the controller by the key ON, the controller display will show “|- -|” after 5 seconds
10.
Press contemporaneously Key 1 and Key 4 for a few seconds to enter PROGRAMMING MODE. The display on the Door Controller
will show “P” and “00” flashing alternately.
11.
When the Door Controller is working in PROGRAMMING MODE the “PROG” red led is on while the other two red leds are off.
12.
When the Door Controller is in PROGRAMMING MODE, all signals coming from the main lift controller and from the external
devices (barriers, photocells, …) are ignored.
13.
Choose parameter 70 increasing or decreasing the value shown on the display through keys 2 and 3 respectively; to confirm the
parameter press key 1, ENTER.
14.
The display will automatically restart in approximately 7 seconds and the SDS controller will get back in AUTO mode, ready to
work.