6.18 IM (REVERSING MOTION) SIGNAL TYPE (PARAM. CODE 34)
This parameter allow to choose 3 different signals to manage the IM (reversing motion) coming from external to main lift controller:
6.18.1
Im pulse.
The IM (reversing motion) is active until KA (door opening relay) arrive from MLC (main lift controller).
6.18.2
IM Continuous (default)
IM (reversing motion) is active up to the end of complete opening of a doors LA (contact limit open doors).
6.18.3
Monostable pulse.
IM (inversion of movement) is active only for a preset time of 0.5 [sec]. After this time interval the output is disabled.
6.19 KB OPTIONS (PARAM. CODE 27)
This function allow IM (KSKB) activation during the door closing in low speed with KB/VRVRT command active.
6.19.1
Rev. Sense Off (Default)
IM/KSKB can't be activate during the closing in low speed
6.19.2
Rev. Sense On
IM/KSKB can be actiovated during the closingh in low speed if:
•
The reopening force exceed the FSET
•
KN (closing edge) input activation
•
Photocel activation if it's connect in the Detector INPUT
After the SDS restart in case of closing with VRVRT th IM/KSKB can not activate.