PM.2.004921.EN - 808-001-000 SDS
©
rel 3 · Edition 22 July 2020
Drive - Instruction Manual
Field wiring terminal marking in accordance with UL508A
Terminals
number
Connection
mode
Typer of
connections
Wiring conductor
type
Wiring
temperature
rating
Tightening
torque
Wire size
AWG UL/CUL
6
Tightening screw
24Vcc Battery
power supply
and Load (Motor
power)
Use Copper Conductors
Only
Not Required
Max 0,6 Nm
Min 0,5Nm
Max 12
Min 30
8
Tightening screw
24Vcc Detector/
Photocell power
supply and control
circuit
Use Copper Conductors
Only
Not Required
Max 0,6 Nm
Min 0,5Nm
Max 12
Min 30
7
Plug type
Motor encoder
Use Copper Conductors
Only
Not Required
Not Required
Not Required
9
Tightening screw
Control circuit
Use Copper Conductors
Only
Not Required
Max 0,6 Nm
Min 0,5Nm
Max 14
Min 30
10
Tightening screw
Copper Conductors Only
Not Required
Max 0,6 Nm
Min 0,5Nm
Max 12
Min 30
11
Tightening screw
Not Required
Max 0,6 Nm
Min 0,5Nm
Max 12
Min 30
12
Plug type
(Terminal not
separable from the
cable)
Main power
supply voltage
Flexible cord in
agreement with UL
category code ZJCZ "Use
Copper Conductors Only"
60°C (140°f)
Not Required
Max 14
Min 18
Sematic Drive System
©
setup incoming/outgoing signals from the door controller
1
= with these motors the complete Sematic Drive System
©
operator acquires the IP43 protection.
2
Safety chains
3
Main Lift Controller
4
Photocells or Detectors