Document: U99_001
page 20 of 24
7.4.2
Change of lip seal
Depending on installation circumstances, pump- and motor size must be decided whether the pump aggregate has to be
partly or totally dismantled from basement.
On principle, complete mechanical seal has to be changed.
Auxiliaries: 0,5 % soapsuds , soft fuzz-free cloth
Comply with following procedure:
Switch-off pump aggregate as per
6.5.2 Switch-off
Remove coupling located on the pump shaft end
Remove Key from pump shaft
Remove old lip seal (A)
Clean pump shaft and seat of the lipseal
Grease the lip seal, the shaft and the lip seal seat with soap water
Slightly put the lip seal on the shaft towards lip seal seat
Take care that the lip seal will not be damaged by the key nut
Place the lip seal into the seat
Put back key in shaft and asselble coupling again.
Ill. 4: Change of lip seal
Restarting must be done as des described in
5. Installation- and assembly instruction
and
6.6. Restarting
.
Pay attention to the corresponding safety instructions!