19
2.
Operation
2.4 InfoWIN
PLUS
The InfoWIN
PLUS
unit is the indicator and operation panel on the boiler. The InfoWIN
PLUS
unit consists of a large
text display, an ON/OFF button with an LED signal lamp indicating Operation (green), a button for manual ope-
ration / chimney sweeper function, as well as four individual menu buttons. The function of each menu button is
displayed on the Menu line.
backlit display
Colours of backlit display:
– White: Normal operation
– Pink:
Information and fault messages
– Red:
Alarm message
During normal operations the backlit display is turned off automatically after 10 minutes if no button is pressed
during this period.
Display
If the boiler is in standby mode or has been in solid fuel/buffer mode for longer than one hour, the display is
turned off completely and only the green LED is lit. The display is turned on again when a button is pressed or if
another operating mode is activated.
Fig. 6
InfoWIN
PLUS
Boiler temperature
Standby
Info
Menu
144
°F
Operating phases are
displayed here, inclu-
ding Standby, Burner
OFF, etc.
Menu line
Signal lamp (LED)
“Operation” green
Full-text display
(illuminated display)
Assignment of buttons to
their specific function
Manual operation and
Chimney sweeper function
ON/OFF button
Menu buttons
The various operating modes are displayed on InfoWIN
PLUS
, together with the corresponding operating phases.
The following
operating modes
exist:
– OFF
– ON (with self-test, lighting ON, lighting OFF)
– Pellet feed
– Solid fuel / buffer mode
– Manual operation
– Chimney sweeper function
– Shut-down procedure
Corresponding
operating phases
:
– Standby, display OFF
– Purging
– Ignition phase
– Flame stabilization
– Modulation mode
– Burnout
– Burner OFF
– Turn off heat generator
è
La belident GmbH Ar t.-N o. : W 08-0 5
DANGER
The ON/OFF Button does not turn OFF the power!
The boiler/heater and all ac-
cessories are still energized! To turn OFF the power (e.g., for repairs), disconnect
the main power via the circuit breaker.