This manual contains important instructions that 

should be followed during installation and main-

tenance of the generator and batteries.  Read 

and understand all instructions in the manual 

before starting and operating the generator set.

USING THE MANUAL

Congratulations on your choice of a Winco genera-

tor set.  You have selected a high-quality, precision 

engineered generator set designed and tested to 

give you years of satisfactory service.   

 

To get the best performance from your new engine 

generator set, it is important that you carefully read 

and follow the operating instructions in this manual.

 

 

 

 

 

 

Should you experience a problem please follow 

the “Troubleshooting Tables” near the end of this 

manual.  The warranty listed in the manual describes 

what you can expect from WINCO should you need 

service assistance in the future.   

 

 

 

TABLE OF CONTENTS

INTRODUCTION 

 

 

 

2

GUIDE TO PRODUCT SAFETY  

 

3

BASIC INFORMATION

 

Description 

 

 

 

4

 

Specifications   

 

 

5

PREPARING THE UNIT  

 

 

 

Unpacking the Unit 

 

 

5

ENGINE GENERATOR INSTALLATION   

 

Installation 

 

 

 

5

 

Fuel Installation  

 

          6,7

 

Vapor Fuel Pressure Tables 

 

8

 

Fuel Conversions 

 

 

8

 

Battery Installation 

 

 

9

 

Connecting Battery Charger 

 

TRANSFER SWITCH INSTALLATION

 

AC Electrical Connections 

        ,2

 

DC Electrical Connections 

 

3

INITIAL START UP 

 

 

   3,5,6

DSE 30 ENGINE CONTROL   

 

4

ASCO 85 SEQUENCE OF OPERATION 

8

FRONT PANEL CONFIGURATION 

 

9

DSE 30 FAULT CODES 

 

 

20

MAINTENANCE 

 

 

 

2

GENERATOR SET OUTLINE   

 

22

GENERATOR SET PAD LAYOUT 

 

23

TROUBLESHOOTING TABLES  

 

24

AC & DC SCHEMATICS  

 

 

25

MAINTENANCE LOG   

 

        26,27

2 MONTH WARRANTY 

 

 

28

PROPER USE AND

INSTALLATION

You must be sure your new engine generator set is:

 

* Properly serviced before starting.

 

* Operated in a well ventilated area.

 

* Properly exhausted and gases safely   

 

   dispersed.

 

* Wired by a qualified electrician.

 

* Operated only for its designed purposes.

 

* Used only by operators who understand

 

  its operation.

 

* Properly maintained.

COPY YOUR MODEL AND 

SERIAL NUMBER HERE

No other WINCO generator has the same serial 

number as yours.  It is important that you record 

the number and other vital information here.  If you 

should ever need to contact us on this unit it will help 

us to respond to your needs faster.

MODEL_

_________________________________

SERIAL NUMBER_________________________

PURCHASE DATE_________________________

DEALER_________________________________

DEALER PHONE # ________________________

Содержание ULPSS15B2E

Страница 1: ...11088 00 60706 207 INSTALLATION AND OPERATORS MANUAL PACKAGED STANDBY SYSTEM ULPSS15B2W E...

Страница 2: ...l Pressure Tables 8 Fuel Conversions 8 Battery Installation 9 Connecting Battery Charger 11 TRANSFER SWITCH INSTALLATION AC Electrical Connections 11 12 DC Electrical Connections 13 INITIAL START UP 1...

Страница 3: ...ground rod driven into the earth 2 FIRE HAZARD Natural gas and L P present a hazard of possible explosion and or fire a Keep fuel containers out of reach of children b Do not smoke or use open flame...

Страница 4: ...r inside or outside instal lation The transfer switch is UL1008 approved A seven day electronic exerciser circuit is installed in the ATS as standard equipment The ATS also contains the power failure...

Страница 5: ...sfer switch The installation must comply with all national state and local codes Before beginning the installation process check the rating of the generator set and its transfer switch rating Be certa...

Страница 6: ...to the fuel solenoid on the unit must be four to six ounces psi per square inch or 7 to 11 inches W C water column These fuel pressures are critical failure to provide the proper pressure can cause ma...

Страница 7: ...led FEET SIZE OF PIPE up to 25 FT 3 4 Pipe 25 100 FT 1 Pipe over 100 FT Consult Factory Allow an additional 3 feet for each standard elbow Do not use street ells restrictive WARNING PERSONAL DANGER Do...

Страница 8: ...ed LP tank size for LP Vapor withdrawal operating at various outside temperatures given in degrees Fahrenheit Celsius TANK TEMPERATURE TANK SIZE 60 F 16 C 150 GALLON 32 F 0 C 250 GALLON 0 F 18 C 500 G...

Страница 9: ...disconnect the nega tive cable first and then the positive cable 5 Be sure all connections are tight and coat the terminals and cable ends with dielectric grease WARNING The electrolyte is a diluted s...

Страница 10: ...11088 00 10 60706 207...

Страница 11: ...that this circuit be fused for 15 amps Terminal block connections have been provided in the customer connection area of the engine generator set See Page 10 for diagram NOTICE The battery tender is no...

Страница 12: ...are removed from main distribution panels and reinstalled in the emer gency distribution panel Suggested circuits freez er refrigerator furnace emergency lights sump pump emergency outlet circuits etc...

Страница 13: ...ative White INITIAL START UP WARNING DO NOT jump start these engine generator sets Starting these units on a low battery of jump start ing them will cause damage to the engine control module Use the f...

Страница 14: ...ote start WILL NOT occur AUTO White Button This button places the module into its Automatic mode This mode allows the module to control the function of the generator automatically The module will moni...

Страница 15: ...l block in the ATS The voltage should be 240 volts plus or minus nominal The frequency should be between 61 5 to 62 hertz Hz The voltage should also be checked between the hot terminals L2 and L6 and...

Страница 16: ...s for control of the ATS and the generator PUSH BUTTONS On the front control display are three push buttons that control the operation of the generator and the ATS CAUTION Before using the transfer te...

Страница 17: ...ctuator Actuator Position clock battery off S2 10 on up off down exerciser off S1 7 on up off down with load or without load without load S1 8 with up without down SETTING THE EXERCISER CIRCUIT Press...

Страница 18: ...11088 00 18 60706 207...

Страница 19: ...s 4 to select the next parameter or 3 to select the previous parameter within the current page When viewing the parameter to be changed press the button The value begins to flash Press 4 or 3 to adjus...

Страница 20: ...ule detects that the engine oil temperature has exceeded the high engine temperature pre alarm setting level after the Safety On timer has expired UNDERSPEED The engine speed has fallen below the unde...

Страница 21: ...MAINTENANCE Reasonable care in preventive maintenance will insure high reliability and a long life for the engine generator set and Automatic Transfer Switch WARNING When performing any type of mainte...

Страница 22: ...11088 00 22 60706 207 ENGINE GENERATOR SET LAYOUT ULPSS15B2W E...

Страница 23: ...23 11088 00 60706 207 ENGINE GENERATOR SET PAD LAYOUT...

Страница 24: ...ked up engine generator set 9 Defective starter fuel solenoid relay s ENGINE CRANKS BUT WILL NOT START 1 Improper fuel pressure being delivered to unit 2 Fuel supply shut off 3 Fuel supply empty 4 Def...

Страница 25: ...25 11088 00 60706 207 AC AND DC GENERATOR SCHEMATIC...

Страница 26: ...11088 00 26 60706 207 MAINTENANCE LOG DATE HOURS ITEM WORK PERFORMED...

Страница 27: ...27 11088 00 60706 207 MAINTENANCE LOG DATE HOURS ITEM WORK PERFORMED...

Страница 28: ...nd fitness for a particular purpose are limited to 12 months or 1000 hours which ever occurs first from date of purchase In no event is WINCO liable for incidental or conse quential damages Note Some...

Отзывы: