![Wilo Helix2.0-VE Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/wilo/helix2-0-ve/helix2-0-ve_installation-and-operating-instructions-manual_983158073.webp)
en
Installation and operating instructions • Drive for Wilo-Helix2.0-VE / Wilo-Medana CH3-LE • Ed.01/2022-06
73
Overview of analogue
input (AI1)
Type of use:
(Discharge) Pressure sensor
Signal type: 0 – 10 V
Current value:
0.0 bar (0.03 V)
Universal
Display text
2.1
Diagnostics help
2.1.4
Overview of analog input (AI1)
2.1.5
Overview of analog input (AI2)
1.
"Diagnostics help"
2.
"Overview of analogue input AI 1" or
3.
“Overview of analogue input AI 2“
status information on analogue input AI 1/AI 2 can be read:
•
Type of use
•
Signal type
•
Current measured value
Example of status of analogue input AI 1:
16.1.5
Overview of double pump connec-
tion
In the “Diagnostics and measured values” menu :
Double pump
connection info
Partner paired and reachable
Partner WCID: 342C243
Partner Address: 2
Partner Name:
WILO PUMP 1123 43c2
Universal
Display text
2.1
Diagnostics help
2.1.6
Double pump connection info
1.
"Diagnostics help"
2.
"Overview of double pump connection"
status information on the double pump connection can be read.
NOTICE
The overview of the double pump connection is only available if a double
pump connection has been previously configured (see chapter 12 “Dual
Double pump operation”).
16.1.6
Overview of pump cycling status
In the “Diagnostics and measured values” menu :
Pump cycling status
Time-based pump cycling:
Switched on Interval: 24 h
Current status:
This pump is running
Next execution in: 23h 56m
Universal
Display text
2.1
Diagnostics help
2.1.7
Pump cycling status
1.
"Diagnostics help"
2.
"Overview of pump cycling status"
Status information on pump cycling can be read:
•
Pump cycling active: Yes / no
If pump cycling is active, the following additional information is available:
•
Current status: no pump running/both pumps running/this pump running/other pump
running
•
Time until next pump cycling
16.2
Measured values
In the menu “Diagnostics and measured values” there are:
Measured values
Operating data
Statistical data
Universal
Displaytext
2.2
Measured values
2.2.1
Operating data
1.
"Measured values"
operating data, measurement data and statistical data are displayed.
In the submenu “Operating Data” the following information can be read:
Содержание Helix2.0-VE
Страница 2: ......
Страница 3: ...3 English 4...
Страница 89: ......
Страница 90: ......
Страница 91: ......