PAGE 88 OF 102
INFLEXION PLUS
OPERATING INSTRUCTIONS
TP-5211901-C
JUNE 2021
WRN 3.07
Unrecoverable
Communication Error
The display board in the
HHRC or PMRC has
power, but the Base
Board is not
communicating with it. It
may be caused by the
HHRC, Base Board,
RCP Board, or any other
device that is using the
RS-485 communication
lines in the system.
On an error, the Base
Board stops the
program, sends out the
error code to the display
devices and 'flashes' the
code on the Base Board
LED. Because one error
can cause others to
follow, the only code that
is displayed/flashed is
the first one that occurs.
Other errors may
happen after that, but
they are not displayed.
Defective HHRC or
defective base board.
Bad or improper
connection in
communications link, or
HHRC is not properly
powered. Check
continuity of the data
lines from the DC power
cable connector to the
HHRC connector. Refer
to System schematic.
Also check that the
shield in the junction box
has a good electrical
connection to the
electronics common at
one end or the other, but
not both
3,08
Microprocessor Error
Internal firmware
detected error
Replace HHRC or
HHRC Display pcb
3,09
RF module Error
Wireless Transmitter/
Receiver did not
properly initialize
Return HHRC to factory
for repair
Table 9-4 Error and Warning Codes for Wireless HHRC
Message
Meaning
Root Issue
Potential Cause
8,07
Unrecoverable
communication error
No successful poll /
response
communication for
250ms
Wireless Control Box is
not 'talking' to any other
board. Check Base
Board flashes and
HHRC display for x,07
8,08
Internal firmware
detected error
Internal state machine
logic has detected an
invalid state transition
Firmware logic error
8,09
RF module error
Wireless plug-in module
did not properly initialize
Bad module
Table 9-3 Error and Warning Codes for HHRC (Continued)
Message
Meaning
Root Issue
Potential Cause
Содержание Inflexion Plus 1.8
Страница 2: ......
Страница 6: ...PAGE 4 OF 102 INFLEXION PLUS OPERATING INSTRUCTIONS TP 5211901 C JUNE 2021 ...
Страница 16: ...PAGE 14 OF 102 INFLEXION PLUS OPERATING INSTRUCTIONS TP 5211901 C JUNE 2021 ...
Страница 30: ...PAGE 28 OF 102 INFLEXION PLUS OPERATING INSTRUCTIONS TP 5211901 C JUNE 2021 ...
Страница 50: ...PAGE 48 OF 102 INFLEXION PLUS OPERATING INSTRUCTIONS TP 5211901 C JUNE 2021 ...
Страница 62: ...PAGE 60 OF 102 INFLEXION PLUS OPERATING INSTRUCTIONS TP 5211901 C JUNE 2021 ...
Страница 80: ...PAGE 78 OF 102 INFLEXION PLUS OPERATING INSTRUCTIONS TP 5211901 C JUNE 2021 ...
Страница 81: ...PAGE 79 OF 102 INFLEXION PLUS OPERATING INSTRUCTIONS TP 5211901 C JUNE 2021 ...
Страница 82: ...PAGE 80 OF 102 INFLEXION PLUS OPERATING INSTRUCTIONS TP 5211901 C JUNE 2021 ...
Страница 94: ...PAGE 92 OF 102 INFLEXION PLUS OPERATING INSTRUCTIONS TP 5211901 C JUNE 2021 ...
Страница 96: ...PAGE 94 OF 102 INFLEXION PLUS OPERATING INSTRUCTIONS TP 5211901 C JUNE 2021 ...
Страница 100: ...PAGE 98 OF 102 INFLEXION PLUS OPERATING INSTRUCTIONS TP 5211901 C JUNE 2021 ...
Страница 102: ...PAGE 100 OF 102 INFLEXION PLUS OPERATING INSTRUCTIONS TP 5211901 C JUNE 2021 11 2 2 PositionIt PI 35 ...