Contents of Package
Wieland Electric GmbH | BA001039 (Rev. A) | 08/2016
62
Item
Description
IP Address
IP address
Period
Period of sending statistical information (in minutes)
SNMP configuration (R-SeeNet)
Every monitor value is uniquely identified by the help of number identifier
OID – Object
Identifier
. For bi-
nary input and output the following range of OID is used:
OID
Description
.1.3.6.1.4.1.30140.2.3.1.0
Binary input BIN0 (values 0,1)
.1.3.6.1.4.1.30140.2.3.2.0
Binary output OUT0 (values 0,1)
.1.3.6.1.4.1.30140.2.3.3.0
Binary input BIN1 (values 0,1
Object identifier for binary input and output
Note!
All
wienet
v3 routers also provide information about internal temperature of the device (OID
1.3.6.1.4.1.30140.3.3) and power voltage (OID 1.3.6.1.4.1.30140.3.4).
Example of SNMP configuration
NOTE