Contents of Package
31
Wieland Electric GmbH | BA001039 (Rev. A) | 08/2016
Item
Description
Switch to backup SIM card
when data limit is exceeded
and switch to default SIM
card when data limit isn’t
exceeded
This parameter enables switching to secondary SIM card or secondary
APN of the SIM card, when the data limit of default APN is exceeded.
This parameter also enables switching back to default SIM card, when
data limit is not exceeded.
Switch to backup SIM card
when binary input is active
switch to default SIM card
when binary input isn’t ac-
tive
This parameter enables switching to secondary SIM card or secondary
APN of the SIM card, when binary input ‘bin0’ is active. If binary input
isn’t active, this parameter enables switching back to default SIM card.
Switch to default SIM card
after timeout
This parameter defines the method, how the router will try to switch
back to default SIM card or default APN.
Switch between SIM card configurations
The following parameters define the time after which the router attempts to go back to the default SIM
card or APN.
Item
Description
Initial timeout
The first attempt to switch back to the primary SIM card or APN shall
be made for the time defined in the parameter Initial Timeout, range of
this parameter is from 1 to 10000 minutes.
Subsequent Timeout
In an unsuccessful attempt to switch to default SIM card, the router on
the second attempt to try for the time defined in the parameter Subse-
quent Timeout, range is from 1 to 10000 min.
Additive constants
Any further attempt to switch back to the primary SIM card or APN
shall be made in time computed as the sum of the previous time trial
and time defined
Switch between SIM card configurations
Example:
If parameter
Switch to default SIM
card after timeout is checked and parameters are set as follows: Initial
Timeout
– 60 min,
Subsequent Timeout 30 min and Additive Timeout
– 20 min, the first attempt to switch
the primary SIM card or APN shall be carried out after 60 minutes. Switched to a failed second attempt
made after 30 minutes. Third after 50 minutes (30+20). Fourth after 70 minutes (30+20+20).
Содержание wienet v3
Страница 12: ...Status 13 Wieland Electric GmbH BA001039 Rev A 08 2016 Mobile WAN status...
Страница 36: ...Contents of Package 37 Wieland Electric GmbH BA001039 Rev A 08 2016...
Страница 48: ...Contents of Package 49 Wieland Electric GmbH BA001039 Rev A 08 2016 OpenVPN tunnel configuration...
Страница 78: ......