WIDOS
Einsteinstraße 5
Phone
+49 7152 9939 0
Wilhelm Dommer Söhne
D-71254 Ditzingen
Fax
+49 7152 9939 40
GmbH [email protected] Internet:
www.widos.de
08.05.2019
Working Instructions WIDOS SPA 600
Page 33 of 42
6.
Diagnosis program
The purpose of the diagnosis program is the control and the modification of stored machine
parameters.
In the following lines all important diagnosis numbers for the function tests are described.
Unappropriate operation of the diagnosis functions may lead to disturbances in the
machine and may destroy components.
The diagnosis functions allow a direct access to the specific parameters of the machine
and have to be operated only by skilled staff.
Display:
2. line:
WIDOS 4600 SPA
09:43 03.05.2004
Basic menu
Press simultaneously buttons <+> and <Enter> to enter the diagnosis program
from the basic menu.
Display:
2. line:
WIDOS 4600 SPA
0000
Enter the diagnosis number
Enter the required diagnosis number by pressing buttons <+>, <
> and <Enter>.
One step back by pressing buttons <Enter> (keeping pressed) and <->.
No. Signification
0010
- The actual temperature (°C) of the heating element is displayed
0011
- The environmental temperature (°C) is displayed
0012 -
The pressure or the force (bar or N) is displayed
0014
- The required heating time which was calculated by the programmed welding
parameters is displayed
0015 -
The
required change over time which was calculated by the programmed welding
parameters is displayed
0016 -
The required time for pressure ramp which was calculated by the programmed
welding parameters is displayed
0017 -
The
required cooling time which was calculated by the programmed welding
parameters is displayed
0018 -
The
required
cooling pressure is displayed
0022
- Selection of SDR / wall thickness in the display
0000 mm
0002 SDR
0023 -
The automatic change to summer or winter time may be switched on or off
0000: change summer / winter time switched off
0001: change summer / winter time switched on