Starting
and
operating
Chapter 5
08.05.2019
Working Instructions WIDOS SPA 600
Page 21 of 42
5.6.2.
Setting the pipe data
Abort and back to basic menu by pressing button <C>.
1 step back by pressing button <Enter> (keeping pressed) and button <->.
Display:
2. line:
WIDOS 4600 SPA
09:43 03.05.2004
Display of the currently set machine type Current time
and date
alternating with: 21°C HE= - - - °C current outside
and heating element temperature
By pressing simultaneously buttons <+> and <
>, the pipe data can be changed
over the keyboard
or if a reading pen is available, the pipe data can be read with the reading pen
(do not press any other button before and move the pen quickly over the bar code).
Display:
2. line:
mat diam wall
PE80 160 14.6
Set the pipe material
Change the material by pressing buttons <+> and <
>,
confirm with button <Enter> and jump to next parameter.
Display:
2. line:
mat diam wall
PE80 160 14.6
Set the pipe diameter
Change the pipe diameter by pressing buttons <+> and <
>,
confirm with button <Enter> and jump to next parameter.
Display:
2. line:
mat diam wall
PE80 160 14.6
Set the wall thickness
Change the wall thickness by pressing buttons <+> and <
>,
confirm with button <Enter> and jump to next parameter.
Display:
2. line:
angle temp
0.00° 214°C
Set the angle (appears only if angles can be welded
with the set machine)
Change the angle by pressing buttons <+> and <
>,
confirm with button <Enter>; the heating element temperature according to
DVS can not be changed.
Display:
2. line:
name of project
WIDOS.............