Starting
and
operating
Chapter 5
08.05.2019
Working Instructions WIDOS SPA 600
Page 27 of 42
5.7.10.
Joining / cooling
Display:
2. line:
cooling
t=3:32 Pi=12
Remaining cooling time (minutes) and actual pressure
alternating with
Display:
2. line:
cooling
Ps=12 Pi=12
Comparison desired and actual pressure
In case of decrease of pressure during cooling time, a beep sound can be
heard. Readjust pressure onto desired pressure.
5.7.11.
Completion of welding
Display:
2. line:
SD card 0000
Welding parameters will be saved on the SD card (if
present).
0000 = Number of weldings saved on the SD card.
Display:
2. line:
tabl. of errors
parameter OK
Display in case of a fault-free welding.
Or:
welding is finished with shortened cooling time:
Display:
2
nd
line:
shorten cooling t
parameter OK
o r
Display:
2. line:
tabl. of errors
TAWURtp9
Display of the errors occured during welding
(s. chapter 5.7.12).
Release pressure (do not separate the pipes).
Open the clamping devices and remove the welded piece.
Back to basic menu by pressing button <Enter>.