Starting
and
operating
Chapter 5
08.05.2019
Working Instructions WIDOS SPA 600
Page 19 of 42
5.6.1.
Setting the machine types
Abort and back to basic menu by pressing button <C>.
One step back by pressing buttons <Enter> (keeping pressed) and <->.
Display:
2. line:
WIDOS 4600 SPA
09:43 03.05.2004
Display of the currently set machine type
Current time and date
alternating with: 21°C HE= - - - °C current
outside and heating element temperature
Next menu by pressing simultaneously buttons <-> and <Enter>
Display:
2. line:
Copy
_
The data is stored from internal RAM to SD-card by <+>
Next menu by pressing button<Enter>
Display:
2. line:
lang. english
?
Select the language
Select the language with buttons <+> and <->
Next menu by pressing button <Enter>
If welding double pipes is possible, the message appears:
Display:
2. line:
pipe in pipe
No
Select double pipe welding
Press button <+> for Yes
Confirm
Yes or No by pressing button <Enter>
Display:
2. line:
Traceability
No
Traceability can be select
Press button <+> for Yes
Confirm
Yes or No by pressing button <Enter>