Kunststoffschweißtechnik
Maintenance / Storage / Transport
Chapter 6
08.10.14 Working
instructions
WIDOS RSC 2000
Page 33 of 63
In order to replace the cutting chain, shut off the main switch and necessarily the
manual switch-on valve at the service unit.
In case the upper pinion has not lowered downwards, pull it
downwards in order that the chain is not tensioned.
Remove the chain first from the upper pinion of the guiding and
then from the lower pinion.
Put the new chain onto the upper pinion and laterally on the
guiding; make sure that cutting chain is located correctly on the
guiding and then put the chain onto the lower pinion.
Shift the vacuum cap back and fix it by the fixing screws.
Switch on the manual switch-on valve at the service unit in order
to have the clamping cylinder tension the cutting chain again.
We recommend to check if the chain is both located and running
correctly.
Adjust the pressure regulator for the cutting chain (below the
table) onto 1 bar.
Activate the main switch.
Put the key switch
to „1“; the control lamp
is lighting up.
Now shift the cutting chain manually on the guiding and check if it
has been mounted correctly.
If everything is ok, put the switch back to „0“ and pull off the key;
the control lamp extinguishes.
Adjust the pressure relief valve back to the requested pressure
(e.g. 4-6 bars).
6.5. How to clean / replace the chip bag
Clean / replace the chip bag if the chip contents reach 150 mm below the fixing
frame.
Guiding
Cutting chain
302 links
(6825,2 mm)
Upper pinion
Lower pinion