The following diagram maps out the drive slots, locations of PSUs, and ESMs. The diagram also identifies
the direction of airflow by labeling the cold and hot aisles.
Figure 2: 4U60 G2 Storage Enclosure Block Diagram
1.2
Specification Summary
The following table is a summary of relevant specs and represents a fully configured enclosure:
Table 1: Specification Summary
Operating
Non-operating
Condition (Fully
Configured)
5°C to 35°C (41°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
Temperature
20°C per hour
5°C per hour
Temperature
Gradient
1°C per 125m above 950m
1°C per 300m above 3000m
Temperature
De-rating
8% to 80% non-condensing
8% to 80% non-condensing
Relative Humidity
30% per hour maximum
30% per hour maximum
Relative Humidity
Gradient
8g 6ms Trapezoidal
3.5g 6ms Pulse vertical shock
Shock
Random 0.6 Grms 10-300Hz
Random 0.25 Grms, 5-10Hz, 0.05 g sine
wave sweep, 10-300Hz
Vibration
8
1
Document Summary
Installation Guide
1.2
Specification Summary