Installation Guide
CB-TP17
Rough-In Box for 17" Wall/Flush Mount Touch Panels
Overview
Wall Mount panels (NXDs) are contained within a metallic outer housing (back
box). This back box is
not removed
when installing the NXD into a Rough-In
Box (CB-TP17). The back box is
only
removed to gain access for the
replacement of the Compact Flash component or upgrade to the VESA housing.
The CB-TP17 Rough-In Box is an optional metallic box that is secured onto a
beam in a pre-wall setting (where no walls or present). Installation procedures
and configurations can vary.
Specifications
WARNING:
INSTALLER, LEAVE A GAP BETWEEN THE STUD AND ROUGH-
IN BOX TO ACCOMMODATE THE DRYWALL/SHEETROCK.
This gap allows the installation of the drywall/sheetrock after the CB-TP17 has
been mounted onto the beams. The stud notching and Rough-In Box installation
must be done prior to any wall installation.
Note:
The most important thing to remember when mounting this Rough-In Box
is that the mounting tabs must be mounted flush against the outside of the
sheetrock. This step determines whether or not the mounting stud is notched
(cutout-out to fit the Rough-In Box).
Pre-Wall Installation of the CP-TP17 Rough-In Box
1.
Measure the distance between the inside of the two selected stud beams.
Most beams have a distance of about 14" to 16". This is too narrow to
accommodate the 17.072" (43.36 cm) wide CB-TP17 Rough-In Box.
2.
Determine whether one or both of the selected stud beams must be
notched (FIG. 2). The determining factor is the flush alignment of the
mounting tabs along the outside of the post-wall sheetrock.
3.
Cutout the notched beam using a height of 13.554" (34.43 cm) (as shown
in FIG. 2) and a depth
equal to the thickness of the drywall
.
Note:
The determining factor in the depth of the cut into the beam is the
thickness of the drywall. The mounting tabs MUST BE FLUSH against the
drywall and therefore, the depth of the notch depends on that thickness.
4.
Insert one side of the Rough-In Box into the indention on the notched stud
and rest the other side of the box against the opposite beam.
5.
Install and secure a shorter horizontal beam below the Rough-In Box. This
beam acts to support the weight of the box from below and should be
secured to both vertical beams (at the sides).
6.
Fasten the CB-TP17 to the
Notched stud/beam
through the stud fastening
holes, located on the inside of the Rough-In Box (FIG. 3), by using either
nails or screws.
7.
Insert a perpendicular block between the
Non-Notched stud/beam
and
the Rough-In Box. This block acts as a bridge to secure the stud/beam to
the CB-TP17 along the stud fastening holes located inside of the box.
8.
Secure the perpendicular block to the
Non-Notched stud/beam
(FIG. 3)
by using either nails or screws.
9.
Fasten the CB-TP17 to the
block
through the stud fastening holes, located
on the inside of the Rough-In Box (FIG. 3), by using either nails or screws.
10. Remove any necessary wiring knockouts from the (optional) Rough-In Box
(CB-TP17) (FIG. 3) where the necessary cables are threaded through for
connection to the touch panel.
11. Thread the incoming RJ-45, Ethernet, and any other audio/video wiring
through the knockouts (use of the top or bottom knockouts are
recommended with this installation).
12. Install the drywall/sheetrock before inserting the main NXD unit into the
CB-TP17.
Installing the 17" panel within a CB-TP17 Rough-In Box
The Rough-In Box must be mounted prior to continuing this section. Verify that
all necessary cables have been threaded through the knockouts on the Rough-In
Box and the connections have been tested prior to installation of the 17" panel.
1.
Remove the magnetic faceplate/bezel (
A
in FIG. 1) from the main NXD unit
(
B
in FIG. 1) by gripping the faceplate and pulling with gentle outward force.
2.
Verify the incoming RJ-45, Ethernet, and any other audio/video cables
have been properly threaded through the wiring knockouts on the left of the
Rough-In Box. Leave enough slack in the wiring to accommodate any
re-positioning of the panel.
3.
Connect all data and power wiring connectors to their corresponding
locations along the side of the (un-powered) NXD touch panel.
• Verify the terminal end of the power cable is not connected to a power
supply before plugging in the 2-pin power connector.
• The USB connectors can be from either a USB extension cable, or a
wireless USB RF transmitter.
Note:
Don’t disconnect the connectors from the touch panel. The unit must be
installed with the attached connectors before being inserted into the CB.
4.
Test the incoming wiring by connecting the panel connections to their
terminal locations and applying power. Verify the panel is receiving power
and functioning properly to prevent repetition of the installation.
5.
Disconnect the terminal end of the power cable from the connected PSN
power supply.
6.
Carefully slide the main NXD unit (
B
in FIG. 1) into the Rough-In Box, so
the Mounting Tab lies flush against the Rough-In Box (
C
in FIG. 1).
7.
Insert and secure four securing #8 flat-head Mounting Screws into their
corresponding holes located along the sides of the NXD.
These #8 screws
are not included within the CB Installation Kit.
8.
Replace the magnet faceplate (
A
in FIG. 1) back onto the main NXD unit.
Make sure to align the Microphone, Light, and PIR Motion sensor locations
to their respective openings on the front bezel/faceplate.
9.
Connect the terminal RJ-45, Ethernet, and any optional audio/video wiring
to their respective locations (outside the Rough-In Box) on either the AVB
breakout box, Ethernet port, or NetLinx Master.
10. Reconnect the terminal power connector on the PSN and apply power.
CB-TP17 (FG034-10) Specifications
Dimensions (HWD) • 13.55" x 17.07" x 3.49"
• 34.43 cm x 43.38 cm x 8.85 cm
Included
Accessories
Rough-In Box Installation Kit (SA2001-02)
• 4 Phillips pan-head (#4-40 x 0.375 Black) screws (80-0115)
• 4 Phillips pan-head (#4-40 x 0.625 Black) screws (80-0118)
Certifications
• cTUVus Listed
FIG. 1
Wall Mount panel installation configuration of a CB-TP17
B
- Main NXD unit consists of
C
- Optional
Four #8 flat-head
(not included)
secure the NXD to
Stud
the touch panel and backbox housing
CB-TP17
Support block
Mounting Tab
Do not
use these
tabs to mount
the Rough-In Box
A -
Faceplate
(bezel)
CB-TP17
Mounting Screws